Subject to the terms and conditions hereof, Parker-Hannifin Corporation (PARKER) warrants that major structural com-
ponents on MCB, PNP, SDC, SFC, and SHM series will be free from defects in materials and workmanship for ten (10) 
years from the date of shipment from Parker. Subject to the terms and conditions hereof,  warrants to the original Buyer 
of any Parker product (PRODUCT) installed and used as recommended by PARKER in normal service, that if the PROD-
UCT fails or is materially defective within twenty-four (24) months from date of installation or thirty (30) months from the 
date of shipment (whichever is earlier), of such PRODUCT, then PARKER, at PARKER’S sole option, will replace the 
PRODUCT with the same or equivalent PRODUCT, repair the PRODUCT or refund the original purchase price for the 
PRODUCT. Such replacement, repair of payment by PARKER shall be in complete satisfaction of any and all liability of 
PARKER and its agents with respect to such PRODUCT. Excluded from any Parker warranty are hose, electrical motors 
or consumable products such as flexible hose, belts, filter cartridges, filter media, ESP cells, electrical components, 
gasketing, or any component defined by PARKER as a consumable item.  

Parker IGFG’s warranty policy covers defects that are due to manufacturing quality. Equipment must be installed, 
commissioned and maintained in accordance with Parker IGFG recommendations as documented in the specific user 
manual related to your dust or wet collector product. This warranty does not cover defects due to poor environmental 
conditions, improper installation, or wear and tear items. This warranty shall be void in case of:  

a) 

Any buyer’s modifications not explicitly approved by Parker IGFG Division,  

b)

 Misuse or failure in maintenance - not in accordance with Parker’s product recommendations,  

c)

 Use of unauthorized or non-genuine Parker replacement parts,  

d)

 Damage caused by corrosion, abrasion, abnormal use or misuse, misapplication, or normal wear and tear,  

e) 

Equipment not properly installed, operated and maintained under normal conditions and  recommended applications.  

As Buyers exclusive remedy for any defects in the equipment, Parker will exchange or repair any defective parts during 
the warranty period, provided such parts are returned, prepaid, to Parker factory.  The obligation of Parker is limited to 
furnishing replacement parts F.O.B. Parker factory or making repairs at Parker factory of any parts that are determined, 
upon inspection by Parker, to be defective.  In no event will Parker be responsible for labor or transportation charges for 
the removal, reshipment or reinstallation of the parts. Replacement parts will be provided via INCOTERMS EXW from 
Parker’s Lancaster NY location. Parker makes no warranty as to goods manufactured or supplied by others.   

THE FOREGOING IS THE ONLY WARRANTY, GUARANTEE OR REPRESENTATION OF ANY KIND MADE WITH RE-
SPECT TO THE SUBJECT PARKER PRODUCTS. NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY 
OF NONINFRINGEMENT, DESIGN, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIES TO 
THE PRODUCT, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED ABOVE, GIVEN 
BY ANY PERSON, FIRM OR CORPORATION WITH RESPECT TO THE PRODUCT SHALL BIND PARKER. PARKER 
SHALL NOT BE LIABLE FOR LOSS OF REVENUES OR PROFITS, EXPENSE FOR SUBSTITUTE EQUIPMENT OR 
SERVICE, STORAGE CHARGES, OR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED 
BY THE USE, MISUSE OR INABILITY TO USE THE PRODUCT REGARDLESS OF THE LEGAL THEORY ON WHICH 
THE CLAIM IS BASED, AND EVEN IF PARKER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. NOR 
SHALL RECOVERY OF ANY KIND AGAINST PARKER BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF 
THE PRODUCT SOLD BY PARKER AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, 
YOU ASSUME ALL RISK AND LIABILITY FOR LOSS, DAMAGE OR INJURY TO YOU AND YOUR PROPERTY AND 
TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE, MISUSE OR INABILITY TO USE THE PRODUCT NOT 
CAUSED DIRECTLY BY THE NEGLIGENCE OF PARKER. THIS LIMITED WARRANTY IS GIVEN ONLY WITH RESPECT 
TO A PRODUCT PURCHASED FROM PARKER OR AN AUTHORIZED PARKER DISTRIBUTOR.

Parker Industrial Gas Filtration and Generation Division

Product Warranty – SMOG-HOG

®

 and 

DUST-HOG

®

 Pollution Control Systems

Summary of Contents for CRYSTAL-AIRE

Page 1: ...Modular Air Cleaning Systems Owner s Manual ...

Page 2: ...t It will also help you understand how to maintain it in order to achieve top performance For quick future reference fill in the system information in the spaces below Should you need assistance call the Parker Customer Service number shown below To expedite your service have the following information available when contacting Parker Unit Model _____________________________________________________...

Page 3: ...nt 9 Ceiling Mount 9 Electrical Requirements 9 How Your CRYSTAL AIRE uv System Operates 10 Blower Module 10 Fan On Off Switch 10 Fan Speed Selector 10 Uvc Lamp 10 Media Filters 10 Odor Filter 10 Filter Status Light 10 Cleaning 11 Blower Module 11 Lamp Breakage Disposal 11 Uvc Lamp 11 Maintenance Service 12 Blower Module 12 UVC Lamp 12 Filter Elements 13 Replacement Parts 14 15 Troubleshooting Guid...

Page 4: ... access cover secured Stay clear of blowers or other moving parts that can cause injuries Do not use in explosive atmospheres Do not use with combustible dusts Use nonflammable cleaners Do not collect emissions which are explosive Keep flammable materials and vapors such as gasoline away from air cleaner The unit should be inspected frequently for correct fan operation UV lamp operation and filter...

Page 5: ...trol of Parker Parker disclaims any liability or responsibility for damage from fires or explosions regardless of origin Parker recommends that all APC dust collection equipment installation and application conform to any and all applicable local state and federal standards codes laws and regulations including the addition of appropriate fire or explosion protection systems including but not limit...

Page 6: ...ion contact your local CRYSTAL AIRE uv distributor or PARKER sales representative NEGATIVE PRESSURE ROOM AIR APPLICATION Your CRYSTAL AIRE uv system can also be configured as a negative air machine where the room in which it is installed will remove extracted air that passed through the filtration and UV chamber from the room thus creating and maintaining a nega tive pressure situation or vacuum w...

Page 7: ...00 1200 1500 2400 SPECIFICATIONS INPUT POWER 115V 1P 60HZ OPERATING CURRENT Amps 12 INPUT POWER CORD LENGTH ft 8 INPUT POWER CORD PLUG NEMA 5 15 MAXIMUM AIRFLOW cfm 800 NOISE RATING dB A 50 65 dBA PREFILTER EFFICIENCY MERV 8 19 3 16 48 1 4 19 15 16 PREFILTER FILTER AREA sq ft 4 8 MAIN FILTER EFFICIENCY 99 97 True HEPA MAIN FILTER FILTER AREA sq ft 113 UV LAMP LIFE ESTIMATE hours 17 000 CABINET DIM...

Page 8: ... rod or eyebolts and chain may be used to hang the unit FALL HAZARD Check the CRYSTAL AIRE uv unit weight on page 7 before installing and ensure the supporting or suspension steel work has sufficient load bearing capacity Wall Mounting 1 Remove the wall bracket from CRYSTAL AIRE uv 2 Locate an appropriate area on the wall to mount the CRYSTAL AIRE uv a To allow for adequate flow allow a minimum of...

Page 9: ...n both the inside and outside of the cabinet to lock the threaded support in place 3 Once the CRYSTAL AIRE uv is mounted replace the front cover 4 Plug in the power cord to appropriate power supply a The CRYSTAL AIRE uv is now ready for operation Note If the optional carbon filter was purchased install it in the appropriate slot located between the blower unit and the out let grille see figure for...

Page 10: ... viral bacterial and fungal organisms An optional final filter can be installed after blower section to help with odors and smells as the air is returned into the space PREFILTER This is a one inch thick disposable MERV 8 filter consist ing of pleated glass fiber media inside a metal frame The filter traps large particles before they can enter the primary filter stage The prefilter evenly distribu...

Page 11: ...s the highest airflow volume at 800 CFM Speed 2 is set to 400 CFM and speed 3 is set to 600 CFM CHANGE FILTER INDICATOR An internal factory set mechanical differential pressure switch attached to a red indicator lamp on front control panel is to indicate when the pre filter or main filter is clogged and requires replacement When the change filter red indicator lamp illuminates it is recommended th...

Page 12: ...voltage transformer MOTOR BLOWER MODULE MOVING PARTS Motors are maintenance free No lubrication is required RISK OF ELECTRIC SHOCK UV LIGHT SOURCE UV LIGHT SOURCE Risk of exposure to ultraviolet radiation Eye damage may result from directly viewing the light from UV lamps UV LAMP BREAKAGE CAUTION Broken Quartz is SHARP Wear PPE including Tyvek suit protective gloves respirator N95 or better and ey...

Page 13: ...roved containment bag and disposed of following installation site guidelines for hazardous waste FILTER CHANGEOUT Replace pre filter every 3 months or when change filter light is illuminated Replace main filter every 36 months or when change filter light is illuminated Replace carbon filter monthly The carbon odor filter is not monitored by the change filter indicator light If the red filter indic...

Page 14: ...4 2909237 Main Filter HEPA 2971351 Power Switch EX0040 1 Fan Speed Selector Switch 20 2755 Indicator Lamp 20 1064 Door Interlock Switch 20 2907 Transformer 20 1062 Differential Pressure Switch 20 1063 Fan Motor 22 10052 Caster GC0007 UV Lamp 20 1066 UV Lamp Ballast 20 1067 Odor Filter 33 10163 Sight Glass Not Shown 40 1040A1 Fan Speed Selector Switch Knob 39 10082 Fure 8A SLOBLO 25 10014 PARTS ORD...

Page 15: ...Optional MERV 13 14 Door Interlock Switch Differential Pressure Switch Speed Selector Switch Transformer UV Lamp Caster Fan Speed Selector Switch Fan Speed Selector Switch Knob Power Switch Indicator Lamp Odor Filter UV Lamp Ballast Fan Motor Fuse ...

Page 16: ...rol switch 3 Check the filter access door is in place and activating the door interlock switch 4 Check that the pre filter is installed and activating the filter interlock switch 5 Check that the interlock switches are operating correctly consult a qualified electrician D Poor air quality 1 Media filters are loaded 2 Main filter is not locked into place and there is air bypass 3 Unit operating at ...

Page 17: ...17 CRYSTAL AIRE uv SYSTEM WIRING DIAGRAM ...

Page 18: ...and maintained under normal conditions and recommended applications As Buyers exclusive remedy for any defects in the equipment Parker will exchange or repair any defective parts during the warranty period provided such parts are returned prepaid to Parker factory The obligation of Parker is limited to furnishing replacement parts F O B Parker factory or making repairs at Parker factory of any par...

Page 19: ...19 ...

Page 20: ...ic Fuel Filtration Division Metamora Ohio 419 644 4311 Industrial Gas Filtration Generation Division Lancaster NY 800 343 4048 Industrial Process Filtration Division Mineral Wells Texas 940 325 2575 Bioscience Engineering Filtration Division EMEA Birtley United Kingdom 44 0 191 410 5121 Engine Mobile Filtration Division EMEA Dewsbury United Kingdom 44 0 1924 487 037 Gas Separation Filtration Divis...