Compax3F device description
Hydraulics Controller
3.2.4.
Analog Input (plug X1)
Connector X1 Pin Description Combicon 3.81mm; female connector
1
24V
Supply Sensor 0
2
GND
Supply Sensor 0
3
IN0+
Signal Sensor 0 +
4
IN0-
Signal Sensor 0 -
5
24V
Supply Sensor 1
6
GND
Supply Sensor 1
7
IN1 +
Signal Sensor 1 +
8
IN1 -
Signal Sensor 1 -
9
24V
Supply Sensor 2
10
GND
Supply Sensor 2
11
IN2 +
Signal Sensor 2 +
12
IN2 -
Signal Sensor 2 -
13
24V
Supply Sensor 3
14
GND
Supply Sensor 3
15
IN3 +
Signal Sensor 3 +
16
IN3-
Signal Sensor 3 -
17
IN4+
+/-10V Input 4
18
IN4-
+/-10V Input 4
19
IN5+
+/-10V Input 5
20
IN5-
+/-10V Input 5
Requirement: Connection cable
Use shielded cables.
Shield connection of the cables
The cable must be fully-screened and connected to the Compax3 housing. Use the
cable clamps/shield connecting terminals furnished with the device.
3.2.4.1
Wiring of the analog current inputs
Input IN0
IN0 to IN3 do have the same wiring!
Pin assignment
(see on page 14) X1
3.2.4.2
Wiring of the analog voltage inputs
Input IN4
IIN4 and IN5 (X11/19 and X11/20) have the same wiring!
10pF
200
KΩ
200
KΩ
In0-
200
KΩ
X1/4
200
KΩ
In0+
X1/3
25
0Ω
Compax3
1nF
22.1
KΩ
100
KΩ
In4+
22.1
KΩ
X1/17
100
KΩ
1nF
In4-
X1/18
2.5V
Compax3
14