68
Medium Flow Compressed Air Dryers - IOMI.
PROBABLE CAUSE
REMEDY
Filtration has not been correctly maintained.
If the element and float drain have been installed longer than 12 months
ensure that they are both changed.
Verify that the float drain is operating correctly.
The inlet parameters have changed.
If the inlet flow-rate has increased ensure that the filters and dryer are re-
sized accordingly.
If the inlet temperature has increased verify that the filters are within speci-
fication. Ensure that the oil vapour removal filters and the dryer are re-sized
accordingly.
If the inlet pressure has changed ensure that the filters and dryer are re-sized
accordingly.
Contact Parker for details on particle counting and air quality air
measurement.
The compressor is not functioning correctly.
Check the documentation supplied by the compressor manufacturer for
troubleshooting guidance.
There is a pressure loss from the system.
Check for leaks in the piping and at connection points.
Ensure that all drain cocks and pressure relief valves are closed.
Check to see if the downstream flow-rate demand has increased.
The dryer is not powered up.
Verify that the dryers power indicator is illuminated. If the dryer is not pow-
ered check the isolator and circuit breaker.
An isolation valve is closed or partially closed.
Check the position of all isolation valves.
PROBABLE CAUSE
REMEDY
Filtration has not been correctly maintained. The compressor
is not functioning correctly.
Check the documentation supplied by the compressor manufacturer for
troubleshooting guidance.
There is a pressure loss from the system.
Check for leaks in the piping and at connection points.
The dryer is not powered up.
Verify that the dryers power indicator is illuminated. If the dryer is not pow-
ered check the isolator and circuit breaker.
Check the dryer fault indicators.
High Pressure drop
A high pressure drop will result in low pressure gauge readings or intermittent operation of the downstream equipment.
Downstream air supply interrupted
An interruption of the air supply downstream will result is a rapid loss of system pressure and failure of the downstream equipment.
Summary of Contents for CDAS HL 050 Series
Page 4: ...04 Medium Flow Compressed Air Dryers IOMI SAFETY...
Page 7: ...07 Medium Flow Compressed Air Dryers IOMI RECEIVING AND INSPECTING THE EQUIPMENT...
Page 9: ...09 Medium Flow Compressed Air Dryers IOMI MODEL OVERVIEW...
Page 13: ...13 Medium Flow Compressed Air Dryers IOMI OVERVIEW OF THE EQUIPMENT...
Page 17: ...17 Medium Flow Compressed Air Dryers IOMI INSTALLATION AND COMMISSIONING...
Page 37: ...36 Medium Flow Compressed Air Dryers IOMI CDAS HL OFAS HL FBP HL OPERATION...
Page 43: ...42 Medium Flow Compressed Air Dryers IOMI OPERATING THE EQUIPMENT...
Page 52: ...51 Medium Flow Compressed Air Dryers IOMI PREVENTATIVE MAINTENANCE...
Page 59: ...58 Medium Flow Compressed Air Dryers IOMI TECHNICAL SPECIFICATION...