Date of Issue: 19 August 2021
Page 8 of 24
QF 80: Issue 2
Parker Hannifin
– Instrumentation Products Division Europe
President Park, President Way, Sheffield,
South Yorkshire, S4 7UR, United Kingdom
Tel: +44 (0) 114 224 0000 Web: www.parker.com/ipd
Globe / Needle Valve (DN10 (⅜”) – DN50 (2”)
Reference Number:
IOM 002
Date:
20 May 2014
Issue:
B
STORAGE:
The equipment packing cases are
NOT
waterproof and should be stored in a weatherproof location
before use.
UNPACKING:
It is recommended that before any item is unpacked, it should be moved as close as possible to its
installed position. This will minimise the possibility of damage during handling.
Before unpacking, items should be checked to ensure their part number is in line with requirements
and/or the purchase order.
The valve should be inspected for damage upon receipt - any problems are to be immediately
reported to Bestobell. This should be done within 48 hours of receipt of goods otherwise a warranty
claim may be rejected.
It is further recommended that each item should only be unpacked immediately before it is required.
Before installation the engineer should check for:
•
Damaged Packaging
•
Bent or Distorted Items
•
Scratches, Dents or Damage
Particular attention should be paid to the sealing faces on the end connection flanges.
TOOLS REQUIRED:
No special tooling is required for the installation of this valve.