![Parker BAS-3015 User Manual Download Page 4](http://html1.mh-extra.com/html/parker/bas-3015/bas-3015_user-manual_3714329004.webp)
3
2 Description
The Parker domnick hunter BAS-3015 / BAS-3015M is a portable breathing air purification system, designed to provide high quality breathable
air to meet breathing air standards for compressed air fed respiratory devices.
The BAS-3015 / BAS-3015M breathing air purifier utilises 3 separate stages of compressed air treatment, combined together in a compact and
robust housing.
1st Stage
- Is a general purpose coalescing filter which reduces particulate down to 1 micron, including water and oil aerosols.
2nd Stage
- Is a high efficiency coalescing filter which reduces particulate down to 0.01 micron, including water and oil aerosols.
3rd Stage
- Is an oil vapour removal activated carbon filter which reduces oil vapour and odours down to 0.003 mg/m
3
.
Pressure to the 4 outlet connections can be controlled and set as desired using the lockable pressure regulator and gauge
.
2.1 Technical Specification
This product will not remove CO, CO2 or toxic gases
BAS-3015 / BAS-3015M
Connections
Inlet
1/2” Hose safety coupler
Outlet
4 x G1/4
Maximum Flow Rate
1200 L/min @ 7 bar g (42 scfm @100 psi g)
Minimum Flow Rate
350 L/min @ 7 bar g (12 scfm @ 100 psi g)
Maximum Inlet Pressure
10 bar g (145 psi g)
Minimum Inlet Pressure
4 bar g(58 psi g)
Maximum Operating Temperature
30
o
C (86
o
F)
Minimum Operating Temperature
1.5
o
C (35
o
F)
CO Monitor (when fitted)
Alarms
Audible
90 dba 5 ppm CO and above
Visual - Internal
Power on LCD light
CO alarm indicator light and indication on display
CO analyser low battery warning and display
CO Monitor
Display - LCD
Sensor - electronic chemical cell type
Power
Integral lithium ion rechargeable battery (non replaceable)
(running time approx. 20hrs)
External 110 - 240 Volt AC power supply