Parker ADAPTOMODE A4A Series Installation, Service And Parts Information Download Page 10

Refrigerating Specialties Division

10

Item

Description

Part No.

Qty.

8-12

Bonnet Assy.-

14,16

See Ports List 1, Page 3

13

Spring, Range A and D

80-1001-15

1

15

Diaphragm Follower, Range A

20-1092-00

1

Diaphragm Follower, Range D

20-1092-01

1

17

Diaphragm, Range A

20-1087-04

1

Diaphragm, Range D

20-1087-04

3

76

Motor (HoneywelI M9A4A)

83-1000-44

1

Motor (Penn M80JAA-2)

83-1000-78

1

77

Cam Lock Screw

90-1001-80

78

Motor Cam

20-4087-11

1

79

Motor Mounting Screw

90-1001-70

8

80

Cam Follower Assembly
   (includes bearing)

20-0416-00

1

Item

Description

Part No.

Qty.

81

 Lock Nut

90-1000-00

1

82

 Pressure Adjusting Screw

90-1000-61

1

83

 Mounting Post (Honeywell)

20-1174-00

4

 Mounting Post (Penn)

20-1174-01

4

84

 Guide Post

20-4037-00

1

85

 Guide Post Locknut

20-4038-00

1

86

 Mounting Plate

20-4093-00

87

 Actuating Stem

20-4006-00

1

88

 Stuffing Box Nut

20-1080-00

1

89

 Packing Ring

20-4092-00

1

90

Stem Insert

20-4035-00

1

 

 MB MOTOR BONNET KIT

  Converts to Electric Compensation (M) Variation any
  A4A or A2 Series Regulator, Range A. (Not for A4AO)
  Includes items 8 and 11 - 17 (same as in Parts List 1),
  and items 76-90.

Kit Type

Range

For Port Sizes

Kit Part No.

MBH

A

20 to 100mm (3/4” - 4”)

83-1000-44K

with Honeywell Motor

MBP

A

20 to 100mm (3/4” - 4”)

83-1000-78K

with Penn Motor

  Order transformer as a separate item; specify
 primary voltage.

Part Numbers with “-K” suffix are kits which include
item numbers shown.

A4AM MOTOR BONNET (Fig. 20)

Summary of Contents for ADAPTOMODE A4A Series

Page 1: ...loose particles should be removed from the flange interior before the regulator is installed between the flanges It is advisable to install a close coupled companion strainer RSF at the inlet of the...

Page 2: ...the way in until the flats on the stem barely protrude from the stuffing box nut Push Piston 30 down against the spring force The piston should move freely down and be returned by the spring force If...

Page 3: ...1 1000 20 1 81 1000 20 1 44 Seal Cap 20 4005 00 1 20 4005 00 1 20 4005 00 1 20 4005 00 1 20 4005 00 1 20 4005 00 1 20 1130 00 1 20 1130 00 1 45 Gasket Flange 81 1000 03 2 81 1000 03 2 81 1000 04 2 81...

Page 4: ...essure from the desired control point upstream of the regulator is connected to the gauge port leading to under the diaphragm Thus the regulator will control the pressure at this point The regulator o...

Page 5: ...same as for A4AO A4AOS OUTLET PRESSURE REGULATOR WITH ELECTRIC SHUT OFF The A4AOS Pressure Regulator controls outlet pressure when the modular solenoid pilot is energized and closes when the solenoid...

Page 6: ...low the disassembly and assembly procedure for the A4A pilot pages 2 and 3 When mounting the pilot place the O Rings 50 into the proper grooves and tighten the Cap Screws 49 evenly The ideal tightenin...

Page 7: ...the flow or stop the flow through the flow paths in the Modudapter When mounted on Pad 2 with the S side out it blocks flow from Path X to Path Z see Fig 13 and 14 A4AS When mounted on Pad 1 with the...

Page 8: ...r controls at the higher pressure setting The S6A Modular Solenoid Pilot Fig 12 is mounted on Pad 1 of the Modudapter the A2D Modular Pressure Pilot Fig 10 is mounted on Pad 2 The 20 to 32 mm 3 4 to 1...

Page 9: ...re exists or in low temperature applications where ice could accumulate on the valve stem the A4AMR with remote pilot can be used The cover should be kept on the motor at all times to protect it from...

Page 10: ...Screw 90 1000 61 1 83 Mounting Post Honeywell 20 1174 00 4 Mounting Post Penn 20 1174 01 4 84 Guide Post 20 4037 00 1 85 Guide Post Locknut 20 4038 00 1 86 Mounting Plate 20 4093 00 87 Actuating Stem...

Page 11: ...olenoid valve Types S4 S5 S6N S7 S8 and S9 SYMPTOM PROBABLE REASON CORRECTION Regulator does not Diaphragm or seat dirty damaged Clean or replace Clean strainer shut off flow or frozen Diaphragm follo...

Page 12: ...pe or valve All hand valves in such locations should be marked warning against accidental closing and must not be closed until the liquid is removed Check valves must never be installed upstream of so...