background image

ETHERNET

Powerlink

Drive I/O Connector

EPL/Ethernet Connector

NOTE

: A box surrounding the pins 

  indicates a requirement for twisted-
  pair wiring.

Warning!

You must connect the drive’s protective conductor 
  terminal, marked with the earth symbol    , to a reliable 
  system Protective Earth. 
The drive’s connector strip terminals are at hazardous 
  voltages when power is applied to the drive, and up to 
  several minutes after power is removed. Lower voltages 
  may still be present for several minutes after power is 
  removed.   
During normal operation, these high voltage terminals 
  must not be accessible to the user.

Signal

Pin

Drive Output Power Connector

MOTOR

BK

BK

W

V

U

Motor Brake Relay

Motor Brake Relay

Motor Safety Earth

Motor Phase

Motor Phase

Motor Phase

Power Supply

Fuse Information

120/240 VAC, 50-60Hz, single phase

RX+  

1

RX–  

2

TX+  

3

Not used   

4

Not used   

5

TX–  

6

Not used   

7

Not used   

8

Signal

Pin

Motor Feedback Connector

Signal

Pin

*

When using the SinCos protocol, pins 

    9 and 13 require twisted pair wiring.

 Drive Status LEDs

Drive Enabled

  Off

  Yellow (flashes in Regen)

  Yellow/Green (alternating)

Drive Disabled

  Off

  Yellow

  Yellow

  Yellow & 1 Green flash

  Yellow & 2 Green flashes

  Yellow & 3 Green flashes

  Yellow & 4 Green flashes

Green

Green 

Green

Red

Off

Red

Red

Red

Red

Red

Enabled

Regeneration active

Autorun mode

No faults, or Ethernet boot (8 sec)

Motor control boot (4 sec)

No bridge power

Bridge fault

Feedback fault

Thermal fault

Other fault

LED State—Left

Right

What it means

 

 Controller & Drive Ethernet Status LEDs

Ethernet Link/Activity

Ethernet Speed

Off

Yellow

Yellow, flashing

Off

Green

No Ethernet link detected

Ethernet link established;
  no activity

Ethernet link established 
  and active

Ethernet 10Mbps

Ethernet 100Mbps

LED 

 

 

State

What it means

 Drive EPL Status LEDs

Off

Off/Green (alternating, 50 ms)

Red/Green (alternating, 50 ms)

Green, 1 flash

Green, 2 flashes

Green, 3 flashes

Green, constant

Red/Green (alternating, 200 ms)

Powering up, searching for Ethernet

Standard Ethernet mode, no error

Standard Ethernet mode, EPL error

Waiting for configuration (followed by
  Start of Cycle frame) 

Waiting for configuration to complete

Ready to operate in EPL mode

EPL mode

Not participating in frame exchange, 
  but observing EPL communications

LED State

What it means

Drive has no internal fuses. For safety, you 
must provide a fuse in each AC input line.
See installation guide for complete information. 
Controller has one accessible fuse by the AC 
power connector. 250 VAC, 2.5A, TD, 5x20 mm. 
See installation guide for complete information. 

Factory installed jumpers
   C1 to L1
   C2 to L2
Remove jumpers to use separate control 
  and motor mains AC power input.

R+

R-

C2

C1

L2

L1

Protective Earth GND

Control Input Power

Control Input Power

External Regeneration Resistor

External Regeneration Resistor

Motor Input Power

Motor Input Power

Drive Mains Power Connector

Ethernet Cable: Use braid over foil twisted-pair 
wiring (straight or crossover).

 Controller CANopen Status LEDs

Green, flickering

Green, 1 flash

Green, blinking

Green, constant

Red, 1 flash
 
  

Red, flickering
 

Red, 2 flashes
  

Red, 3 flashes

Red, constant

Off

AutoBaud detection is in progress, or LSS services are 
   in progress (alternately flickering with red LED)

Stopped—Device is in the stopped state

Pre-operational—Device is in the pre-operational state

Operational—Device is in the operational state

Warning Limit Reached—At least one of the error 
   counters of the CAN controller has reached or 
   exceeded the warning level (too many error frames)

AutoBaud detection is in progress, or LSS services are 
   in progress

A guard event (NMT-slave or NMT-master) or a 
   heartbeat event (heartbeat consumer) has occurred

SYNC message has not been received within the 
   configured communication cycle period time out 
   (see Object Dictionary Entry 0x1006)

BUS off—CAN controller is bus off

Reset—controller is executing a reset

LED State

What it means

Axis disabled, no fault

Axis enabled, no fault

Axis fault; motion on axis disabled

LED State

What it means

 Controller Axis Status LEDs

Off

Green

Red

NOTE:

 LED illuminates red whenever the drive fault input 

is activated.

 Drive IP Address Switches

Set IP address/node ID with drive’s rotary decimal switches. 
Ex: set 14 by rotating x10 switch to 1 and x1 switch to 4 (valid 
range is 01 to 99; 00 not valid). IP addresses are 192.168.100.xx, 
with xx being drive’s switch setting.

 Controller EPL Network Status LEDs

Off

Green
   Flickering

   1 flash

   2 flashes

   3 flashes

   Constant

   Blinking

Reset or not active—MN is off, initializing, or 
  in reset state

Basic Ethernet—Node operating as a basic
  Ethernet device, not EPL

Pre-Operational 1—MN asking node status & 
  configuring CNs; full EPL cycles not started

Pre-Operational 2—Full EPL cycles started, 
  node confguration not finished, data ignored 

Ready to operate—CN has responded to 
  request from MN; exchanged data ignored

Operational—Network exchanging valid data

Stopped—Network has stopped

LED State

What it means

 

Red 

    Indicates error state, obtained via P37386

0

 

2 3 4

 5

 6

 7 

8 9

0

 

2 3 4

 5

 6

 7 

8 9

EPL
Status

Drive
Status

Address
Switches

See front cover for controllerLED locations.

Input 0+

 

  

 

1

Input 0– 

 

14

Input 1+

 

  

 

2

Input 1– 

 

15

Input 2+

 

  

 

3

Input 2– 

 

16

High-Speed Input 4+    4

High-Speed Input 4–  17

High-Speed Input 5+    5

High-Speed Input 5–  18

High-Speed Input 6+    6

High-Speed Input 6–  19

Input 3+ 

 

  7

Input 3– 

 

20

Not used   

  8

Not used   

21

Output 0+   

  9

Output 0–   

22

Output 1+   

10

Output 1–   

23

Output 2+   

11

Output 2–   

24

Output 3+   

12

Output 3–   

25

Not used   

13

ENC Z+/DATA+ 

1

ENC Z–/DATA– 

2

DGND  

3

+5 VDC (250mA max)  4

+5 VDC (250mA max)  5

DGND  

6

ENC A–/SIN– 

7

ENC A+/SIN+ 

8

Hall 1/SCLK+ 

*

 

9

 

10

Thermal–  

15

ENC B–/COS– 

11

ENC B+/COS+ 

12

Hall 2/SCLK– 

*

 13

Hall 3 

 

14