Chapter 1, ACR1200 Motherboard Hardware Set-Up
27
ACR1200 MOTHERBOARD HARDWARE WIRING
Encoder Inputs (P1), continued.
A fused +5VDC Encoder Output (EVCC) is available on the P1 connector for use with
wiring the encoders. The maximum recommended output rating for EVCC is
100 milliamps per encoder (300 milliamps, maximum).
See Figure 1 for fuse F2 location.
E5VDC Output Fuse
Fuse
Circuit
Amps
Littelfuse Part No.
F2 EVCC
0.750 154.750
Table 2.13
ACR1200 Encoder Power Fuses