![Parker AC30 series Product Manual Download Page 23](http://html.mh-extra.com/html/parker/ac30-series/ac30-series_product-manual_755681023.webp)
17
AC30 series General Purpose I/O Option
Volt-free Relays (7004-01-00 only)
The 7004-01-00 option contains two general-purpose relays for use as
user outputs.
Terminal
Name
Range
Description
X23
01 RLY11A
See
specification
below
Terminal A of relay 11
(default = unassigned)
02 RLY11B
Terminal B of relay 11
(default = unassigned)
03 RLY12A
Terminal A of relay 12
(default = unassigned)
04 RLY12B
Terminal B of relay 12
(default = unassigned)
Important safety information
:
Insulation and routing of wiring to the relay terminals must be
appropriately rated to ensure the correct degree of insulation to other user
wiring, including the motor thermistor, both inside and outside the drive.
Programming
Parameter
Access
Bit
Value
Description
00022
Write
or
Read
0 to 13
x
These bits control other
I/O on this board and on
the base control board.
14
0
RLY11 is OFF. Contacts
are open.
1
RLY11 is ON. Contacts
are closed.
15
0
RLY12 is OFF. Contacts
are open.
1
RLY12 is ON. Contacts
are closed.