Square Rail Bearing Lubrication
See Section on
Internal Access
(Chapter 6) for procedure to access interior of positioner.
Materials Required:
Replacement Square Rail Bearing Lubrication (See below for
lubrication type and ordering information), Clean Cloth, Small Brush
Lubrication Type for 404xr Series:
For positioners with Clean Room Preparation
‘R1’ and ‘R5’
, Class 1000 compatible (standard): Use
Kyodo Yushi Multemp PS #2
. Contact
:
Kyodo Yushi at +1-630-595-2020 or www.kyodoyushi.co.jp/eng/
for additional technical information, direct purchase or local distributor information.
For positioners with Clean Room Preparation
‘R2’ and ‘R6’
Class 10 compatible: Use
Braycote 803
.
Contact: Castrol Industrial at 800-621-2661 for additional technical information, direct purchase or local
distributor information.
Lubricant Appearance:
‘R1’ and ‘R5’ -
Off-White, smooth but slightly tacky
‘R2’ and ‘R6’
- Translucent-white, smooth and buttery
Lubrication Type for 406xr Series:
For positioners with Clean Room Preparation
‘R1’ and ‘R5’
, Class 1000 compatible (standard): Use
Shell GADUS S2 V100 2. Contact
:
1+800-840-5737 for all of your service needs. Information is also
available on the World Wide Web: http://www.shell-lubricants.com/ for additional technical information,
direct purchase or local distributor information.
For positioners with Clean Room Preparation
‘R2’ and ‘R6’
Class 10 compatible: Use
Braycote 803
.
Contact: Castrol Industrial at 800-621-2661 for additional technical information, direct purchase or local
distributor information.
Lubricant Appearance:
‘R1’ and ‘R5’ -
amber colored
,
smooth-textured
‘R2’ and ‘R6’
- Translucent-white, smooth and buttery
Maintenance Frequency:
For
‘R1’, ‘R2’, ‘R5’,
and
‘R6’
Preparations: Square rail bearing blocks are lubricated at our facility prior
to shipment. For lubrication inspection and supply intervals following shipment, apply grease every 1000
hours of usage for a typical clean environment. The time period may change depending on frequency of
use and environment. Inspect for contamination, chips, etc, and replenish according to inspection
results.
Lubricant Application (No Easy Lube):
For both
‘R1’,
and
‘R2’
Preparations: Wipe the rails down the entire length with a clean cloth. Apply
lubrication on the rails, using a small brush, allowing a film of fresh grease to pass under the wipers and
into the recirculating bearings.