404/406XR Series Product Manual
Chapter 5 - Component Mounting Procedures
26
Parker Hannifin Corporation
1140 Sandy Hill Road
Irwin, PA 15642
www.parkermotion.com
Chapter 5 - Component Mounting Procedures
Center Drive Motor Mounting
Tools Required: Allen Key, Phillips Head
Slip coupling over drive shaft and tighten the screw on the drive shaft side of the coupling.
Note: Do
not use Loctite on coupling screws.
Slide motor into motor adapter plate and into coupling. Select the appropriate hardware and tighten
all bolts.
Tighten the coupling screw on the motor shaft side. Turn motor by the rear shaft to make sure
carriage moves. Then hold carriage and rotate motor again by the rear shaft to make sure coupling
won’t slip. If the motor does not have a rear shaft be certain that the coupling screws are tight.
Note: Do not use Loctite on coupling screws.
Parallel Motor Mounting
Tools Required:
Allen Key M2, M2.5, M3, M4, M5 and Depth Micrometer
Purpose: Parallel Motor Mounting is employed whenever a shorter overall unit is needed. The motor is
positioned along the sides or bottom of the table (designated by position A, B, or C). See Figure 1.
Locate 404/406XR series linear positioner motor mount. Determine correct motor mount required. If
necessary, remove any motor, coupling, adapter plate, and coupling housing.
Identify the correct parallel mounting position, which is desired (Position A, B, or C).
Position B
Position C
Position A
www.comoso.com