![Parker 401XE Series Product Manual Download Page 26](http://html1.mh-extra.com/html/parker/401xe-series/401xe-series_product-manual_3817406026.webp)
401/402/403XE Series Product Manual
26
Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
Payload Mounting
Payload is mounted to the 401/402/403XE using four tapped holes in the carriage. When fastening to the
carriage, take precaution in using screws with no more than6mm of engagement for the 401XE, 13mm of en-
gagement for the 402XE, and 15mm of engagement for the 403XE as to not damage the positioner. See
Chapter 2 for hole sizes and locations.
Accessory transition plates are available to build X
-
Y configurations with various table combinations. If doing
so, be certain not to exceed the moment load specifications outlined in Chapter 2. See Appendix A for transi-
tion plate drawings and part numbers.
Use Appropriate Length Bolt
The 401/402/403XE design requires proper size bolts to be used when mounting payloads to the car-
riage. Excessive length bolts can cause damage or pin the table in position.
Riser Plates
Most of the motors used with the 401/402/403XE have a taller profile than the positioner. Thus the motor can
interfere with the positioner mounting surface. To accommodate taller motors, riser plates can be provided to
space the unit above the mounting surface. See Appendix A for riser plate drawings and part numbers.