401/402/403XE Series Product Manual
23
Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
Chapter 3
-
Component Specifications
Motor Information
The M* motor options supply a Parker servo or stepper motor assembled to the positioner. For specifications
and setup and connection parameters, refer to the motor user guides available for download from
www.parkermotion.com.
The limit/home switch installed on the 401XE,402XE and 403XE is
a hall effect sensor tripped by a magnet located in a housing at-
tached to the carriage. On the switch body is an LED to indicate
activation. Normally open (N.O.), normally closed (N.C.), current
sinking (NPN) and current sourcing (PNP) variations are selectable
with the product. Normally open sensors are typically used for
home and normally closed are typically used for limits. With a cur-
rent sinking sensor, the output lead provides a path to ground
when activated, and with a current sourcing sensor, the output
lead provides a positive (+) voltage potential relative to ground.
Refer to you controller
’
s manual for compatibility. Limit/home
switch information is below.
Limit/Home Switch Information
-
401/402/403XE
401/402/403XE Limit/Home Switch Wiring Code
Power (+)
Brown
Output Signal
Black
Ground (
-
)
Blue
401/402/403XE Limit/Home Switch Specifications
HA or LA Option
HB or LB Option
HC or LC Option
HD or LD Option
Switch Type
N.C.
N.O.
N.C.
N.O.
Logic
NPN
NPN
PNP
PNP
Operating Voltage
10
-
30 VDC
Voltage Drop
2.5 VDC Max
Continuous Current
100 mA
Repeatability
100 µm Max
Reverse Polarity Protection
Yes
Short Circuit Protection
Yes
Power
-
Up Pulse Suppression
Yes
Enclosure Rating
IP67
Operating Temperature Range
-
25°C to +75°C
Cable Length
3.0 m from Switch