Bulletin HY25-1135-M1/US
Owner’s Manual
Parker Hannifin Corporation
Chelsea Products Division
Olive Branch, MS 38654 USA
47
Power Take-Off Maintenance
6 and 8-Bolt PTOs
Due to the normal and sometime severe torsional vibrations that Power Take-Off units experience, operators
should follow a set maintenance schedule for inspections. Failure to service loose bolts or Power Take-Off leaks
could result in potential auxiliary Power Take-Off or transmission damage.
Periodic PTO MAINTENANCE is required by the owner/operator to ensure proper, safe and trouble free
operation.
Daily
:
Check all air, hydraulic and working mechanisms before operating PTO Perform maintenance as
required.
Monthly
: Inspect for possible leaks and tighten all air, hydraulic, and mounting hardware, if necessary. Torque
all bolts, nuts, etc. to Chelsea specifications. Ensure that splines are properly lubricated, if applicable.
Perform maintenance as required.
With regards to the direct mounted pump splines, the PTO requires the application of a specially formulated
anti-fretting, high pressure, high temperature grease. The addition of the grease has been proven to reduce the
effects of the torsional vibrations, which result in fretting corrosion on the PTO internal splines as well as the
pump external splines. Fretting corrosion appears as a rusting and wearing of the pump shaft splines. Severe
duty applications, which require long PTO running times and high torque may require more frequent regreasing.
Applications such as Utility Trucks that run continuously and are lightly loaded also require frequent regreasing
due to the sheer hours of running time. It is important to note that service intervals will vary for each and every
application and are the responsibility of the end user of the product. Chelsea also recommends that you consult
your pump owners manuals and technical services for their maintenance guidelines. Fretting corrosion is caused
by many factors and without proper maintenance the anti-fretting grease can only reduce its effects on
components.
Chelsea offers the grease to our customers in two packages. The first is a 5/8 fluid ounce tube (379688), which is
included with every applicable PTO, and the second is a 14-ounce grease cartridge (379831). Chelsea also
offers greaseable shafts for most output option designators for select PTO Series.
Warranty: Failure to comply entirely with the provisions set forth in the appropriate Owner’s Manual will
result in voiding of ALL Warranty consideration.
Summary of Contents for 221 Series
Page 4: ...Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA IV...
Page 36: ...32 Notes Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA...
Page 37: ...Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA 33 ALLISON...
Page 43: ...Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA 39 DODGE RAM...
Page 52: ...48 Notes Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA...
Page 53: ...49 Notes Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA...
Page 54: ...50 Notes Parker Hannifin Corporation Chelsea Products Division Olive Branch MS 38654 USA...