Maintenance and repair of the dryer
BSP-MT 10-95/D3
37
Maintenance work to be completed every 12 months
Check air quality
Especially for critical applications, we recommend to annually check the quality of the pro-
cessed medical breathing air (this check should be carried out by a qualifi ed authority).
Renew muffl ers
The dryer is equipped with a muffl er. If the muffl er becomes blocked, a dam pressure is gen-
erated which in extreme cases may cause the muffl er to burst.
Hazard caused by blocked muffl er!
Blocked muffl ers can cause a dangerous overpressure to build up which may
cause the muffl ers to burst. Flying fragments may cause personal injury and
damage to property.
Therefore, the muffl ers must be replaced every 12 months and after each
change of desiccant.
Warning against sudden air ejection!
During expansion the pressure is released suddenly through the muffl er:
◊ A loud cracking noise occurs which can injure your hearing.
◊ Particles carried in the air fl ow act like bullets and can injure your eyes or
skin.
Always wear eye and ear protection, therefore, when you are in the vicinity of
the dryer!
Depressurise the dryer and shut it down
(see page 30 ).
Unscrew muffl er as shown in the opposite
fi gure.
Replace muffl er and secure it.
Restart dryer (see page 31).
Undo muffl er
Replace the element in the fi ne fi lter muffl er
Depressurise the dryer and shut it down
(see page 30 ).
Undo knurled screw on the lid cap and
remove cap.
Unscrew old fi lter element. Arrows on the
element bottom mark the direction of rotation.
Insert new fi lter element and screw on
tightly.
Renew muffl er element
Re-engage lid cap at the top section of the housing and fi x in position by means of the
knurled screw.
Restart dryer (see page 31 ).
Summary of Contents for BSP-MT 10-95/D3
Page 2: ......
Page 54: ...EN User Manual Annex with technical documentation 52 BSP MT 10 95 D3 Flow diagram ...
Page 55: ...EN User Manual Annex with technical documentation BSP MT 10 95 D3 53 Dimensional drawing ...
Page 56: ...EN User Manual 54 BSP MT 10 95 D3 ...
Page 57: ...EN User Manual BSP MT 10 95 D3 55 ...
Page 58: ...EN User Manual 56 BSP MT 10 95 D3 ...
Page 59: ......