Parker Hiross Hypercool ADP004 User Manual Download Page 3

1

English

ADP004-075 

1.  Safety instructions

!

 Every unit is equipped with an electric disconnecting switch 

for operating in safe conditions. Always use this device in order to 
eliminate risks maintenance.

!

 Th

  e manual is intended for the end-user, only for operations 

performable with closed panels: operations requiring opening 
with tools must be carried out by skilled and qualifi ed personnel.

Y

 Do not exceed the design limits given on the dataplate.

!

Y

 It is the user’s responsibility to avoid loads diff erent from 

the internal static pressure. Th

  e unit must be appropriately pro-

tectedwhenever risks of seismicphenomena exist.

!

 Th

  e safety devices on the compressed air circuit must be pro-

vided for by the user.

Before starting any maintenance operations, make sure that the 
circuits are not under pressure.

Only use the unit for professional work and for its intended pur-
pose.

Th

  e user is responsible for analysing the application aspects for 

product installation, and following all the applicable industrial and 
safety standards and regulations contained in the product instruc-
tion manual or other documentation supplied with the unit.

Tampering or replacement of any parts by unauthorised personnel 
and/or improper machine use exonerate the manufacturer from all 
responsibility and invalidate the warranty.

Th

  e manufacturer declines and present or future liability for dam-

age to persons, things and the machine, due to negligence of the 
operators, non-compliance with all the instructions given in this 
manual, and non- application of current regulations regarding 
safety of the system.

Th

  e manufacturer declines any liability for damage due to altera-

tions and/or changes to the packing.

It is the responsibility of the user to ensure that the specifi cations 
provided for the selection of the unit or components and/or op-
tions are fully comprehensive for the correct or foreseeable use of 
the machine itself or its components.

When requesting technical assistance or ordering spare parts, al-
ways quote the model and serial number on the identifi cation plate

mounted externally on the unit.

IMPORTANT:Th

  e manufacturer reserves the right to modify 

this manual at any time.

For the most comprehensive and updated information, the user 
is advised to consult the manual supplied with the unit.

2.  Introduction

Foreword

Read this manual carefully to ensure that you install and operate 
this unit correctly.

Transport / Handling

•   Use lift ing equipment of suitable capacity to lift  and move the 

unit (fork lift  etc.).

•   Protect the unit from impact to prevent damage to internal 

components.

•   Th

  e manufacturer assumes no liability for damages

•   Which may be caused by decayed or modifi ed packaging.

Inspection

As soon as you receive the unit, check its condition;

 if you notice 

any damage inform the carrier immediately.

3.  Assembly (see Fig. 1)

N.B.: 

For fl anged models, if the optional counterfl anges/gaskets 

kit has not been acquired these must be supplied by the user.

3.1 -   Mounting aft ercooler

Th

  e unit can either be wall mounted (using customer supplied 

brackets) or fl oor mounted using the legs, either supplied as stand-
ard or available as an optional depending upon the model.

3.2 -   Mounting the legs (see Fig. 3)

Place the aft ercooler (1) upside down on the ground; screwthe legs 
(3) onto the bottomplate (2) using the nuts and bolts (4).

3.3 -   Mounting separator model STH

Screw the separator onto the aft ercooler outlet (for models

 

004-

014 use the curve (4 - Fig. 3)).

3.4 -   Mounting separator model SFH

Connect one gasket and counterfl ange respectively to the aft er-
cooler inlet and separator outlet, using the supplied bolts. Place 
the third gasket between the aft ercooler outlet and separator inlet, 

and connect those using the supplied bolts.

3.5 -   Models 018-038 without separator

Connect one gasket and counterfl ange respectively to the aft er-

cooler inlet and outlet, using the supplied bolts.

Summary of Contents for Hypercool ADP004

Page 1: ...4 CODE 398H272981 air cooled aftercooler pneumatic version Hypercool ADP004 075 English 1 User manual Italiano 4 Manuale d uso Deutsch 7 Benutzerhandbuch Français 10 Manuel d utilisation Nederlands 13 Gebruikershandleiding ...

Page 2: ......

Page 3: ...ons are fully comprehensive for the correct or foreseeable use of the machine itself or its components When requesting technical assistance or ordering spare parts al ways quote the model and serial number on the identification plate mounted externally on the unit IMPORTANT The manufacturer reserves the right to modify this manual at any time For the most comprehensive and updated information the ...

Page 4: ...nsed gases can react to produce acids and other chemicals which could damage the unit Take particular care with sulphur ammonia chlorine and installations in marine environments For further advice or as sistance consult the manufacturer e Support the air gas inlet and outlet pipes if they strain the connection ports and or flanges f If the unit is installed in a seismic zone install suitable devic...

Page 5: ...ed at least once during each working cycle using the manual drain valve Do not use solvents for the cleaning of the cup Pressure calibration is carried out using the regulation lever checking firstly that the lever is lifted out of its safety lock position turning it clockwise to increase the pressure and anti clockwise to decrease pressure An increase in pressure increases the velocity of the fan...

Page 6: ...eve dibile dell unità stessa o dei componenti Per identificare l unità modello e numero di serie in caso di ri chiesta di assistenza o di ricambi leggere la targhetta di identifica zione posta esternamente all unità ATTENZIONE Il costruttore si riserva il diritto di modifica re le informazioni contenute nel presente manuale senza alcun preavviso Ai fini di una completa ed aggiornata informazione s...

Page 7: ...to potrebbe produrre acidi o prodotti chimici in grado di danneg giare l unità Fare attenzione allo zolfo all ammoniaca al cloro e all installazione in ambiente marino Per consigli o assistenza contattare il costruttore e Predisporre opportuni sostegni per le tubazioni di ingresso ed uscita aria gas nel caso in cui queste sollecitino pericolosamen te i relativi bocchelli e o le flange di collegame...

Page 8: ...one Drenare la tazza almeno una volta per ogni turno di lavoro agendo sull apposita valvola di scarico manuale Per la pulizia della tazza non usare solventi La regolazione della pressione si effettua agendo sulla manopo la di regolazione accertandosi prima che sia sbloccata dalla posizione di anti manomissione sollevata per aumentare la pressione ruotare la manopola in senso orario antiorario per ...

Page 9: ... in vernünftiger Weise vorhersehbare Nutzung der Anlage bzw der Bauteile ausreichen Die Kenndaten des Geräts Modell und Seriennummer für Re paratur oder Ersatzteilanforderungen sind auf dem außen ange brachten Geräteschild ablesbar ACHTUNG Der Hersteller behält sich das Recht vor die in dem vorliegenden Handbuch enthaltenen Informationen ohne Vorbescheid zu ändern Zur vollständigen und aktuellen I...

Page 10: ...ische Stoffe erzeugen die das Gerät beschädigen könnten Hierbei ist insbesondere auf Schwefel Ammoniak Chlor und die Installation in Umgebungen mit Seeklima zu achten Für Ratschläge oder Kundendienst wenden Sie sich bitte an den Hersteller e Die Leitungen für den Luft Gas Einlass und Auslass sind mit geeigneten Halterungen zu versehen falls sie die zugehörigen Mundstücke und oder die Verbindungsfl...

Page 11: ...chenden manuellen Ablass ventils ausführen Zur Reinigung des Bechers auf keinen Fall Lösungsmittel verwenden Die Einstellung desDrucks erfolgt am entsprechenden Regler Bediengriff zuvor ist sicherzustellen dass dessen Entsperrung aus der Zugriffssicherheitsposition ausgeführt wurde d h in angehobener Stellung zur Erhöhung des Drucks den Regler Bediengriff im Uhrzeigersinn drehen zu dessen Verminde...

Page 12: ...que les conditions fournies pour la sé lection de l unité ou de ses composants et ou options sont parfaite ment conformes pour une utilisation correcte de cette même unité ou de ses composants Pour identifier l unité modèle et numéro de série en cas de de mande d assistance ou de pièces détachées lire la plaquette d iden tification qui se trouve sur l extérieur de l unité ATTENTION Le fabricant se...

Page 13: ...es acides ou des produits chimiques susceptibles d endommager l unité Faire attention au soufre à l ammoniaque au chlore et à l installation en milieu marin En cas de besoin de conseils ou d assistance contacter le fabricant e Munir de supports appropriés les tuyaux d entrée et de sortie de l air gaz s ils sollicitent dangereusement les bouches et ou les brides de raccordement relatives f Prévoir ...

Page 14: ...haque fois qu une nouvelle équipe commence en agissant sur la soupape d évacuation manuelle N utilisez pas de solvants pour nettoyer le godet Réglez la pression en agissant sur lamanette de réglage après avoir vérifié qu elle n est plus en position de sûreté soulevée pour augmenter la pression tournez la manette dans le sens des aiguilles d une montre pour la réduire tournez dans le sens inverse L...

Page 15: ...rect of rede lijkerwijs voorspelbaar gebruik van de unit of van de onderdelen te garanderen Bekijk het identificatieplaatje op de buitenzijde van de unit om de unit te identificeren model en serienummer wanneer er service of vervangingsonderdelen nodig zijn LET OP de fabrikant behoudt zich het recht voor de informatie in dit handboek zonder enige waarschuwing vooraf te wijzigen Voor volledige en a...

Page 16: ...emische producten produceren die de unit zouden kunnen beschadigen Let op zwavel ammoniak en chloor en bij installatie in omge ving van zeewater Neem voor adviezen of hulp contact op met de fabrikant e Zorg voor goede steunen voor de in en uitgangsleidingen van de lucht het gas indien deze gevaarlijke druk uitoefenen op de aansluitpoorten en of flenzen f Zorg voor geschikte beschermingen tegen sei...

Page 17: ...ed past De opvangbak moet minstens één keer per werkcyclus worden gereinigd via het manuele aftapventiel Gebruik geen oplosmiddelen omde opvangbak te reinigen De druk wordt gekalibreerd met de regelhendel waarbij u eerst controleert dat de hendel niet meer in het veiligheidsslot zit Draai de hendel rechtsom om de druk te verhogen en linksom om de druk te verminderen Bij een drukverhoging stijgt de...

Page 18: ... 1 5 4 5 1 3 user utenza 500 min Fig 2 Outdoor positioning user utenza 3 5 5 4 1 2 Fig 3 Mounting the legs INSTRUCTIONS S Place the aftercooler 1 upside down on the ground S Screw the legs 3 onto the bot tom plate 2 using the nuts and bolts 4 ...

Page 19: ...P004 075 Fig 4 Overall dimensions Aftercooler Separator STH Filter Reducer Lubricator Pressure Gauge assembly see Fig 5 compressed air flow cooling air flow no 4 holes 4 14 no 4 holes 4 13 ADP004 014 ADP018 ...

Page 20: ... 410 1126 456 Model air in out FR L connections weight volume nominal air flow pneumatic motor air consumption air pressure matching separator kg dm3 m3 min 1 m3 min 2 bar ADP004 threaded 1 BSP 3 8 F 37 3 7 3 5 0 15 16 STH013 ADP006 58 4 6 0 2 ADP009 threaded 2 BSP 70 6 6 9 0 4 STH021 ADP014 106 9 1 14 0 5 ADP018 flanged PN16 DN80 UNI 2278 67 1 2 F 146 17 6 18 0 8 Weight and volume are for afterco...

Page 21: ...1975 702 2263 482 241 905 110 1800 903 1510 412 1576 478 Model air in out FR L connections weight kg volume dm3 nominal air flow m3 min 1 pneumatic motor air consumption m3 min 2 air pressure bar matching separator ADP018 flanged PN16 DN80 UNI 2278 67 1 2 F 146 17 6 18 0 8 16 STH029 ADP028 154 18 9 28 3 ADP038 langed PN16 DN100 UNI 2278 67 211 35 9 36 STH037 Weight and volume are for aftercooler o...

Page 22: ...230 239 1051 2800 496 2866 562 Model air in out FR L connections weight kg volume dm3 nominal air flow m3 min 1 pneumatic motor air consumption m3 min 2 air pressure bar matching separator ADP048 flanged PN16 DN150 UNI 2278 67 1 2 F 391 64 9 48 6 16 STH067 ADP064 429 73 2 64 ADP075 476 81 75 STH088 Weight and volume are for aftercooler only for separator see respective manual 1 7 barg 120 C inlet ...

Page 23: ...TERISTICS Maximum pressure 10 bar Minimum pressure 5 bar Maximum temperature 50 C Fig 6 Spare Parts List MODEL FAN PNEUMATIC CONTROL FR L ASSEMBLY ADP004 398H384050 398H281750 398H354541 ADP006 398H384051 ADP009 398H384052 398H281751 ADP014 398H384053 ADP018 398H384057 398H281753 ADP028 398H384141 x 1 398H281755 x 1 398H354545 x 1 ADP038 ADP048 398H384141 x 2 398H281755 x 2 398H354545 x 2 ADP064 A...

Page 24: ... Corsico MI Italy Sede Operativa Hiross Zander Filtration Division Strada Zona Industriale 4 35020 S Angelo di Piove PD Italy tel 39 049 971 2111 fax 39 049 9701911 Web site www parker com hzd e mail technical support hiross parker com A division of Parker Hannifin Corporation ...

Reviews: