background image

 

4.5    Assembly of the side rails (optional)           

 

IMPORTANT 

– 

Please  ensure  that  the  side  rail  is  located  fully,  correctly  and  securely  into  the  integral 

bracket, and that the hand-screws are tightened up fully to lock the side-rail in position before use. 

 

 

The side rails must be fitted into the integral brackets as illustrated below, ensuring that they are pushed all the way 

down to the bottom of the bracket. 

 

 

The hand-screws must then be fitted onto the inside of the bracket and tightened fully to correctly and securely fix 

the side rails in place. The hand-screws have a fine thread. They are different to those used to securing the bed 

frame. 

Do not over tighten. 

 

 

 

4.6  Using the integral bed frame extension (optional)                                       

 

IMPORTANT  - 

The  bed  must  only  be  extended  at  the  foot  end.  When  extending  the  bed,  only  the 

approved extension panel should be used, and this 

MUST

 be fitted. 

 

 

Remove the  lock-pins  and  loosen  the  hands-screws 

on the foot frame.   

 

Pull the foot frame out from the sleeping platform until 

the second set of holes on the T brackets match the 

fixing holes on the side frame. 

 

 

Insert the lock-pins and tighten 

‘hand-screws’ on both 

sides.   

Do not over tighten. 

 

Fit the mesh extension panel

 

on top of the extended 

T bracket.   

 

 

Note:

   

This extension panel is an optional accessory. If you require this accessory please contact Park House 

Healthcare Ltd. Tel: 0845 0600 333.

 

 

Summary of Contents for Tudor

Page 1: ...Tudor Bed User Manual...

Page 2: ...s 5 4 4 Correct positioning of the cables 5 4 5 Assembly of the side rails optional 6 4 6 Using the integral bed frame extension 6 5 Operating instructions 7 5 1 Operation of the height adjustment and...

Page 3: ...and cleaning the bed in the space between the undercarriage and mattress platform the adjustment functions on the handset must be locked to avoid unintentional activation of the mattress platform The...

Page 4: ...ead end has one mesh section and foot end has two sections IMPORTANT The head and foot frames MUST be fitted to the correct ends of the sleeping platform IMPORTANT Please make sure that for normal use...

Page 5: ...Black Backup battery plug Optional accessory 4 4 Correct positioning of the cables The cables must be connected in the correct manner to avoid trapping the cables between the metal parts of the bed du...

Page 6: ...d They are different to those used to securing the bed frame Do not over tighten 4 6 Using the integral bed frame extension optional IMPORTANT The bed must only be extended at the foot end When extend...

Page 7: ...the Locked condition The handset will resume locked condition with the LED not lit when there has been no further operation within 30 seconds The handset will resume locked condition with the LED unl...

Page 8: ...height Under no circumstances must the bed be moved by pulling or pushing the side rails either when the bed is occupied or empty Siderails are not designed for this purpose Never exceed the maximum...

Page 9: ...g storage or transportation you should always use the storage transport frame To use this frame please comply with the following steps Disconnect the mains power plug and carefully roll up the power l...

Page 10: ...et connections 3 Contact Park House Healthcare Ltd WARNING Any unauthorized modifications adjustments or alterations will result in warranty invalidation Repairs should only be carried out by a suitab...

Page 11: ...s Protection The Tudor bed offers IP66 Ingress Protection on all electrical components and controls as standard This is a very high level of protection which is completely dustproof and capable of bei...