Guidance and manufacturer’s declaration –electromagnetic emissions 

The Vios

TM

 is intended for use in the electromagnetic environment specified below. The customer or the user of the 

 Vios

TM

 should assure that it is used in such an environment.  

Emissions test  

Compliance

Electromagnetic environment – guidance  

RF emissions
CISPR 11

Group 1  

The Vios

TM

 uses RF energy only for its internal function. 

Therefore, its RF emissions are very low and are not
likely to cause any interference in nearby electronic  
equipment.

RF emissions
CISPR 11

Class   B

Harmonic emissions 
IEC 61000-3-2

 Not applicable

Voltage fluctuations /
flicker emissions  
IEC 61000-3-3

Not applicable

The Vios

TM

 is suitable for use in all establishments,  

including domestic establishments and those directly 
connected to the public low-voltage power supply 
network that supplies buildings used for domestic 
purposes.

Guidance and manufacturer’s declaration –electromagnetic immunity

The Vios

TM

 is intended for use in the electromagnetic environment specified below. The customer or the user of the Vios

TM

 should  

assure that it is used in such an environment.  

Immunity test

IEC 60601 test level

Compliance level

Electromagnetic environment 

guidance

Conducted RF 
IEC 61000-4-6 

Radiated RF 
IEC 61000-4-3 

3 Vrms 
150 kHz to 80 MHz 

3 V/m 
80 MHz to 2,5 GHz 

3 Vrms 
150 kHz to 80 MHz 

3 V/m 
80 MHz to 2,5 GHz 

Portable and mobile RF communications equipment 
should be used no closer to any part of the Vios

TM

,  

including cables, than the recommended separation  
distance calculated from the equation applicable to the 
frequency of the transmitter. 

Recommended separation distance  

P

V

d

=

1

P

E

d

=

1

80 MHz to 800 MHz

P

E

d

=

1

7

  800 MHz to 2,5 GHz

where 

P

is the maximum output power rating of the 

transmitter in watts (W) according to the transmitter 
manufacturer and 

d

 is the recommended separation 

distance in metres (m).
Field strengths from fixed RF transmitters, as deter-
mined by an electromagnetic site survey, 

a

should be less 

than the compliance level in each frequency range. 

b

Interference may occur in the vicinity of equipment 
marked with the following symbol:  

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.  
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection 
from structures, objects and people.  

a

 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the 
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the 
measured field strength in the location in which the Vios

TM

 is used exceeds the applicable RF compliance level above, the   

Vios

TM

 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be  

necessary, such as re-orienting or relocating the Vios

TM

.

b

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [

V

1

] V/m.

3,5

3,5

Questions? 1.800.FAST.NEB (327.8632)  |  PARI.com/VIOSPRO

EN-10

Summary of Contents for Vios PRO

Page 1: ...STRUCTIONS FOR THE PARI LC PLUS NEBULIZER IMPORTANT READ INSTRUCTIONS AND SAFETY PRECAUTIONS BEFORE USE READ ALL WARNINGS AND INSTRUCTIONS BEFORE USE USE THE PRODUCT ONLY FOR ITS INTENDED USE AS DESCR...

Page 2: ...d Never use when sleeping or drowsy 5 This product contains small parts that may present a choking hazard to small children The tubing also presents a strangulation hazard ALWAYS USE CLOSE ADULT SUPER...

Page 3: ...arized plug one blade is wider than the other As a safety feature this plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug 5 Never block the...

Page 4: ...n hand at all times PARI Reusable Nebulizer Holder Air Outlet Air Filter Questions 1 800 FAST NEB 327 8632 PARI com VIOSPRO EN 3 Power Switch Vios PRO Tubing PARI Reusable Nebulizer 2 included Inspira...

Page 5: ...e to the nebulizer outlet with the expiratory valve facing up Then attach the inspiratory valve cap by pressing it firmly into the top of the nebulizer If using a mask attach mask to the nebulizer out...

Page 6: ...fficient treatments Bacterial contamination can be reduced Questions 1 800 FAST NEB 327 8632 PARI com VIOSPRO EN 5 E TIMESTRIP It is very important to replace your PARI reusable nebulizer every 6 mont...

Page 7: ...me as your PARI reusable nebulizer For filter replacement obtain the replacement filter set part 085F0012P2 which includes the filter and the filter removal tool Fig F Push the filter tool firmly over...

Page 8: ...ention Read all Instructions for Use before operation Insulation enclosed Class II equipment Type B Protection from electrical shock Do not dispose of in unsorted municipal trash Please consult local...

Page 9: ...ER EXPRESS WARRANTIES ALL IMPLIED WARRANTIES ON THE Vios PRO Aerosol Delivery System AND ITS PARTS INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO S...

Page 10: ...M be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a...

Page 11: ...than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance P V d 1 P E d 1 80 MHz to 800 MHz P E d 1 7 800 MHz...

Page 12: ...PLUS IMPORTANTE LEA LAS INSTRUCCIONESY PRECAUCIONES DE SEGURIDAD ANTES DE USAR EL DISPOSITIVO LEA TODAS LAS ADVERTENCIAS E INSTRUCCIONES ANTES DE UTILIZAR EL EQUIPO USE EL PRODUCTO S LO PARA EL PROP S...

Page 13: ...se mientras duerme o est somnoliento 5 El producto contiene piezas peque as que pueden presentar un riesgo de asfixia para ni os peque os La entubaci n adem s presenta un riesgo de estrangulaci n SIEM...

Page 14: ...m s ancha que la otra Una caracter stica de seguridad de este enchufe es que se enchufa a un tomacorriente polarizado en s lo un sentido Si el enchufe no encaja totalmente en el tomacorriente d lo vu...

Page 15: ...e PARI Salida de aire Filtro de aire Timestrip Ubicaci n sugerida de Timestrip Tiene preguntas 1 800 FAST NEB 327 8632 PARI com VIOSPRO ES 3 Interruptor el ctrico Entubaci nVios PRO Nebulizador reutil...

Page 16: ...hacia arriba Luego cierre la tapa de la v lvula de inspiraci n al presionarla firmemente en la parte superior del nebulizador Si usa una mascarilla con ctela a la salida del nebulizador y referir a su...

Page 17: ...do de la burbuja Verifique la activaci n Aparecer una l nea roja en el c rculo peque o de la pegatina Timestrip en 1 2 minutos lo que indica la activaci n Si no observa la l nea roja despu s de 3 minu...

Page 18: ...za de repuesto de filtro 085F0012P2 la cual incluye el filtro y la herramienta de desmontaje del filtro Fig F Empuje firmemente la herramienta del filtro por sobre el filtro y gire la herramienta de d...

Page 19: ...nsaci n Presi n atmosf rica 500 hpa a 1060 hpa EXPLICACI N DE S MBOLOS Atenci n Lea todas las Instrucciones de uso antes de usarlo Equipo de aislamiento cerrado Clase II Protecci n tipo B contra choqu...

Page 20: ...IMPL CITAS DEL Sistema de Suministro por Aerosol Vios PRO Y SUS PIEZAS INCLUIDAS LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD Y ADECUACI N PARA UN PROP SITO PARTICULAR SE LIMITAN A SESENTA 60 MESES A...

Reviews: