QUESTIONS ABOUT TRIO? 1-888-335-6946

   

|

  

1

TABLE OF CONTENTS

A

Introduction ............................................................................. 1

B

Safety Precautions And Important Safeguards ........................... 2

C

Getting Started .......................................................................... 3

D

Using “AA” Batteries .............................................................. 4

E

Using Optional AC Power Supply ................................................ 4

F

Trio Nebulizer Handset Assembly ..................................... 5-6

G

Taking A Treatment ............................................................... 6-7

H

Trio Nebulizer Handset Cleaning ....................................... 8-9

I

Trio Nebulizer Handset Disinfection .................................... 10

J

Functionality Test ......................................................................... 10

K

Frequently Asked Questions And Troubleshooting .................. 10-11

A

INTRODUCTION

These Instructions For Use contain information and safety precautions

for the Trio

®

 Electronic Nebulizer. Save these Instructions For Use for

future reference.

Before using your Trio Electronic Nebulizer, you should read and understand

the entire Instructions For Use. If for any reason you do not understand

any part of these Instructions For Use, please call the toll free number

below before proceeding with your treatment.

Take special note of all safety precautions marked DANGER and WARNING.

INDICATIONS FOR USE

The Trio Electronic Nebulizer is a handheld nebulizer that will be used with

patients for whom doctors have prescribed medication for nebulization.

The Trio Electronic Nebulizer is intended for adult and pediatric patients.

Summary of Contents for Trio

Page 1: ...ral law restricts this devicetosalebyoronorderofaphysician Read and understand these Instructions for Use and all safety precautions it contains Improperusecancauseserious or fatal injury and or illne...

Page 2: ...on and safety precautions for the Trio Electronic Nebulizer Save these Instructions For Use for future reference BeforeusingyourTrioElectronicNebulizer youshouldreadandunderstand the entire Instructio...

Page 3: ...NEVER operate the Controller if it is improperly or incompletely assembled or damaged Section G Taking a treatment shows the alerts to these situations when the Trio Electronic Nebulizer is improperl...

Page 4: ...o not have all the items please call the number listed below FOUR AA BATTERIES MEDICATION RESERVOIR AEROSOL CHAMBER MOUTHPIECE WITH EXHALATION VALVE AC POWER SUPPLY AEROSOL HEAD INHALATION VALVE CARRY...

Page 5: ...eries will provide approximately 2 hours of continuous treatment You may also use AA rechargeablebatteries Pleasesee Specifications ontheback cover of these Instructions For Use NOTE IT IS STRONGLY RE...

Page 6: ...fingers Figure 8 F TRIO NEBULIZER HANDSET ASSEMBLY WARNING TheTrioNebulizerHandsetisnotsterile CleanandDisinfecttheTrio NebulizerHandsetbeforethefirstuse seeSectionHforCleaningand SectionIforDisinfect...

Page 7: ...withTrioElectronic Nebulizer a Trio Nebulizer Handset Attached To Controller Place the Controller on a clean flat stable surface Slide the Trio Nebulizer Handset into the Controller cradle as far as i...

Page 8: ...en delivered a You will hear the Treatment Complete Alarm 2 beeps and 2 green lights b The Trio Electronic Nebulizer will automatically shut off 10 If for any reason you must stop the treatment before...

Page 9: ...bulizerHandsetimmediatelyaftereveryuse Donot wash the Controller Nebulizer Connection Cord AC Power Supply or PlugConverters Useliquidsoapdesignedforwashingdishes Donot use white liquiddishsoaps e g I...

Page 10: ...f clear liquid dish soap to a clean bowl or basin and add warm tap water Figure 28 5 Wash all parts of the Trio Nebulizer Handset and rinse thoroughly under running warmtapwater Figure 29 If Disinfect...

Page 11: ...ain after the treatmentintheMedicationReservoir Ifmorethanafewdropsremain cleantheAerosolHead SectionH If afterpropercleaning morethan afewdropsremainintheMedicationReservoir call1 888 335 6946 QUESTI...

Page 12: ...batteries following the procedure in Section D Please note that the Controller has a built in automatic shutoff after 10minutes anditwillturnoffatthattime Ifthissituationcontinues three or four times...

Reviews: