SafeAir
™
M-350 Pro Installation Guide
5
https://parazero.com/
1.2
Technical Specifications
The SafeAir
™
M-350 Pro system should only be operated in open air and in normal weather
conditions.
Technical Specifications
Criterion
Specification
Expected Reaction Time
Up to 50ms
Minimum safe altitude
30.39m (99.7ft) AGL
Average descent rate
at maximum takeoff weight 9kg (19.84lbs)
4.41m/s (14.46ft/s)
Total system weight
900g (1.98lbs)
Temperature Range
-20°C to +60°C (-4°F to +140°F)
when the system is fully charged
Maximum Wind Speed/Flight Speed
55knots
Humidity
90% @ 35°C (95°F)
Parachute repack cycle
2 years
Maximum number of deployments
15
Service life
5 years
Maximum Takeoff Weight
9kg (19.84lbs)
Maximum altitude above mean sea level
3,000m (9,842ft)
*ISA, at zero wind and stabilized vertical speed.
1.3
Maintenance
The SafeAir
™
M-350 Pro system should undergo period maintenance procedures once every
two years. The first periodic maintenance schedule is set for two years from the manufacturing
date and appears printed on the system itself and on its box.
The maintenance should be performed by ParaZero or a designated, certified agent.
For more information, please contact