background image

 

SafeAir

 M-350 Pro Installation Guide 

13

 

https://parazero.com/ 

5.4

 

Inserting the Pyro actuator 

 

Caution

 

 

During all installation stages, be sure 

 

 

That the safety pin remains in its proper place 

 

Not to connect the parachute cable to the SmartAir 

 

1

 

Unscrew  the  safety  transportation  capsule  and  take  out  the  pyro-actuator.  When 
removing the pyro-actuator from the transport capsule, you are obliged to use protective 
glasses as a safety precaution. 

2

 

Insert the pyro-actuator into the socket in the bottom of the container, ensuring that you 
insert completely to the end of the connection point. 

 

 

 

 

Summary of Contents for SafeAir M-350 Pro

Page 1: ...SafeAir M 350 Pro ASTM F3322 22 Compliant INSTALLATION GUIDE Pending...

Page 2: ...Pyro Actuator 12 5 5 Inserting the Parachute 14 REMOTE CONTROLLER OPTIONAL 16 6 1 RC 1 0 System Ports Switches 16 6 2 RC 1 0 System Status and Troubleshooting 17 6 3 RC 1 0 System Specifications 17 6...

Page 3: ...publication are owned by ParaZero Drone Safety Systems and protected by applicable copyright laws and international treaty provisions ParaZero Drone Safety Systems retains all rights not expressly gr...

Page 4: ...speed hover 2 A completely autonomous identification and activation capability using the dedicated SmartAir Pro autonomous triggering system ATS 3 A DJI M350 dedicated independent flight termination...

Page 5: ...y charged Maximum Wind Speed Flight Speed 55knots Humidity 90 35 C 95 F Parachute repack cycle 2 years Maximum number of deployments 15 Service life 5 years Maximum Takeoff Weight 9kg 19 84lbs Maximum...

Page 6: ...SafeAir M 350 Pro System The system incorporates a safety pin which acts as an on off button and electrically prevents the activation of the system Do not remove the safety pin until specifically inst...

Page 7: ...rachute box 4 The parachute folded between a red base and a yellow cap 5 4 strings Tools and cables box 6 USB C cable for the SAP 7 TerminateAir cables for electronic TerminateAir M 350 1x long black...

Page 8: ...ir Connectors Overview A 2 Stage Safety pin Stage 1 Power on off Stage 2 Pyro safety B FTS UART connector optional Vin PWM C USB C connector D Parachute cable connector E RGB LED F Inner buzzer G Exte...

Page 9: ...n the parachute system on the mounting bracket the SAP should face the rear of the drone 3 Attach the four screws four spring washers and four washers in this order Tightly secure the screws using the...

Page 10: ...battery locker in the locked position while the batteries are not installed Use adhesive tape to prevent the remaining parts from ejecting or popping out during the process 2 Use the provided large Al...

Page 11: ...tween the upper port of the left electronic TerminateAir unit and the FTS port of the SAP Notice that the white line on the connector and on the port should match 7 Install the drone s batteries and l...

Page 12: ...re first use Charging should be made while the RC is turned off Caution When the RC is turned off or there is no link between the RC and the receiver manual triggering is not available 3 Using the des...

Page 13: ...to connect the parachute cable to the SmartAir 1 Unscrew the safety transportation capsule and take out the pyro actuator When removing the pyro actuator from the transport capsule you are obliged to...

Page 14: ...eep the paper container in a safe place for repack purposes 2 Do not remove your hand from the top of the parachute With your other hand leave the parachute main strap with the carabiner attached to i...

Page 15: ...achute and secure the carabiner 6 Secure each parachute string to its designated conduit on the electronic TerminateAir The strings should not obstruct the DJI M350 RTK sensors nor the propellers The...

Page 16: ...Pro Installation Guide 16 https parazero com 6 Remote Controller optional Follow the correct model of your RC 6 1 RC 1 0 System Ports Switches LED Lanyard hole Power switch Charging port Trigger swit...

Page 17: ...No link SafeAir might be turned off or the RC is too far from the receiver 5 Yellow beep every 20 seconds RC battery low The RC will have enough power for 15 minutes It is advisable to end mission and...

Page 18: ...SafeAir M 350 Pro Installation Guide 18 https parazero com 6 4 RC 2 0 System Ports Switches...

Page 19: ...20 60 Battery is critically low 0 20 RC Signal strength Signal is at 75 100 Signal is at 50 75 3 long beeps every 5 seconds Signal exists and below 50 3 short beeps every 5 seconds No signal Paired Sa...

Page 20: ...RC messages SA Pyro Error System detected an issue with the parachute SA Orientation System is not level SA Critical Bat SafeAir battery is critically low SA Low Bat SafeAir battery is low SA Flash Er...

Page 21: ...cable The main screen shows the charging status Note the percentage updates every few minutes The following indication shows means low power Charge the RC when this indication shows 6 8 RC 2 0 System...

Page 22: ...1 Make sure that the parachute cable is inserted 2 Try using the pyro dummy 3 Make sure that a pyro is installed 4 Contact ParaZero support Flickering Yellow x1 NA RC channel is disconnected or in act...

Page 23: ...surface Solid Red Triggered Repeating beeping pattern with increasing frequency System was triggered and parachute deployed None Flickering Red x3 Repeating 3 beep pattern System battery is low Finish...

Page 24: ...GREEN RC 2 0 should display the Idle Screen Turn on the power to the drone and verify that the electronic TerminateAir LEDs are on For RC equipped systems perform the FTS test as outlined on item 8 5...

Page 25: ...t to power the motors during the test This checklist assumes that the preflight checks are complete 1 Disconnect the parachute cable from the SAP and connect the pyro dummy Press the middle button on...

Page 26: ...pin is put back into the SAP and RC is turned off the drone will power up again 5 Carefully remove the safety pin then turn on the RC At the end of the initialization process the SmartAir LED should b...

Page 27: ...ent analysis 9 2 Repacking the parachute Inspect the parachute and ensure there is no damage to the parachute lines or the main parachute strap Inspect the canister SmartAir connectors and the Termina...

Page 28: ...ght cells under the folded parachute 6 Fold the left and right part of the folded parachute over each other in an accordion fashion Fold one side to the middle and then fold the other side on top of i...

Page 29: ...e the used pyro actuator from the socket in the bottom of canister 9 Place a new pyro actuator in place according to the above mentioned procedure 10 Place the red base into the bottom of the canister...

Page 30: ...Telephone 972 36885252 Email support parazero com Address 30 Dov Hoz St Kiryat Ono Israel 5555626 https parazero com Operate Drones Everywhere Safely...

Reviews: