background image

 

SafeAir™ M-300 Pro Installation Guide 

8

 

www.parazero.com 

 

 

4

 

 

 

 

SmartAir Connectors Overview 

 

 

 

 

 
 
 
 
 
 
 
 
 

A – 2 Stage Safety pin 
       Stage 1 – Power on/off 
       Stage 2 – Pyro safety 
B – External damper holders 

 
 
 

A – Safety pin 
B – FTS/UART connector 
     (+optional Vin & PWM) 
C – USB-C connector 
D – Parachute connector 
E – RGB LED 
F – Inner buzzer

 

 

 

Front side 

Summary of Contents for SafeAir M-300 Pro

Page 1: ...SafeAir M 300 Pro INSTALLATION GUIDE ...

Page 2: ...Legs to the Drone 9 5 2 Connecting the electronic TerminateAir 10 5 3 Flight Preparations 12 5 4 Inserting the Pyro actuator 12 5 5 Inserting the parachute 14 REMOTE CONTROLLER OPTIONAL 16 6 1 RC System Ports Switches 16 6 2 RC System Status and Troubleshooting 17 6 3 RC System Specifications 17 SYSTEM LED INDICATIONS 18 OPERATING GUIDELINES 20 8 1 Preflight 20 8 2 Takeoff 20 8 3 Before Landing 20...

Page 3: ...one Safety Systems and protected by applicable copyright laws and international treaty provisions ParaZero Drone Safety Systems retains all rights not expressly granted No part of this publication may be reproduced in any form whatsoever or used to make any derivative work without prior written approval by ParaZero Drone Safety Systems All other trademarks are the property of their respective owne...

Page 4: ... completely autonomous identification and activation capability using its dedicated SmartAir Pro Autonomous Trigger System 3 A DJI M300 dedicated independent flight termination system called TerminateAir The M300 TerminateAir controls the power supply of the drone for emergency shutdown The system is designed for fast assembly and detachment using only four tool free screws The SafeAir M 300 Pro d...

Page 5: ... fully charged Maximum Wind Speed Flight Speed 55knots Humidity 90 35 C 95 F Parachute repack cycle 2 years Maximum number of deployments 15 Service life 5 years Maximum Takeoff Weight 9kg 19 84lbs Maximum altitude above mean sea level 3 000m 9 842ft ISA at zero wind and stabilized vertical speed 1 3 Maintenance The SafeAir M 300 Pro system should go under period maintenance procedures once every ...

Page 6: ... pin which acts as an on off button and electrically prevents the activation of the system Do not remove the safety pin until specifically instructed to do so in this guide This manual explains how the SafeAir M 300 Pro works and how to properly operate the system on the ground and in the air Be sure to take the time to read this manual carefully in order to increase your safety and the safety of ...

Page 7: ... the system Parachute box 4 The parachute folded between a red base and a yellow cap 5 4 strings Tools and cables box 6 USB C cable for the SAP 7 TerminateAir cables for electronic TerminateAir M 300 1x long black cable 1x short black cable 8 TerminateAir locker 9 4 screws to connect the main bracket to the mounting bracket 4 washers 4 spring washers large and small Allen keys The Remote Controlle...

Page 8: ...o com 4 SmartAir Connectors Overview A 2 Stage Safety pin Stage 1 Power on off Stage 2 Pyro safety B External damper holders A Safety pin B FTS UART connector optional Vin PWM C USB C connector D Parachute connector E RGB LED F Inner buzzer Front side ...

Page 9: ...r part of the drone by screwing the four thumb screws 2 Position the parachute system on the mounting bracket the SAP should be face the rear of the drone 3 Attach the four screws four spring washers and four washers in this order Tightly secure the screws using the small Allen key The parachute cable should be inserted through the carbon plate as indicated in the photo ...

Page 10: ...cker Position the battery locker in the locked position while the batteries are not installed Use adhesive tape to prevent the remaining parts from popping out during the process 2 Use the provided large Allen key to unscrew and remove the battery locker Keep the battery locker and its parts in a safe location 3 Screw the TerminateAir locker until secured and remove the adhesive tape ...

Page 11: ...on the port should match 6 Use the short black cable to connect between the upper port of the left electronic TerminateAir unit and the FTS port of the SAP Notice that the white line on the connector and on the port should match 7 Install the drone s batteries and lock the TerminateAir locker Use the TerminateAir locker exactly as the previous battery locker to remove or reinstall the batteries 8 ...

Page 12: ...d off Caution When the RC is turned off or there is no link between the RC and the receiver manual triggering is not available 3 Using the desktop application allows for firmware update automatic download of flight logs and system configuration Disconnect the FTS cable and the parachute cable from the SAP Take out the safety pin all way and connect the SAP to your computer using the provided USB C...

Page 13: ...ns in its proper place Not to connect the parachute cable to the SmartAir 1 Unscrew the safety transportation capsule and take out the pyro actuator when taking out the pyro actuator from the transport capsule you are obliged to use protective glasses 2 Insert the pyro actuator into the socket in the bottom of the container make sure you push it all the way in ...

Page 14: ... the paper container out keep the paper container in a safe place for repack purposes 2 Do not remove your hand from the top of the parachute With your other hand leave the parachute main strap with the carabiner attached to it outside of the canister facing the SAP Place the yellow cap make sure the cap is secured and that the parachute is not sticking out of the cap 3 Secure the carabiner into p...

Page 15: ... the carabiner of the parachute and secure the carabiner 6 Secure each parachute string to its designated conduit on the electronic TerminateAir The strings shouldn t obstruct the sensors nor the propellers The strings should climb in a straight line from the conduit and upwards ...

Page 16: ...SafeAir M 300 Pro Installation Guide 16 www parazero com 6 Remote Controller optional 6 1 RC System Ports Switches LED Lanyard hole Power switch Charging port Trigger switch Belt clip ...

Page 17: ...arge complete 4 3x Red flashes beeps No link SafeAir might be turned off or the RC is too far from the receiver 5 Yellow beep every 20 seconds RC battery low The RC will have enough power for 15 minutes It is advisable to end mission and charge the RC 6 Magenta flashes Trigger switch problem Try to manually release the Trigger switch and then turn the RC off and on again 6 3 RC System Specificatio...

Page 18: ...1 Make sure that the parachute cable is inserted 2 Try using the pyro dummy 3 Make sure that a pyro is installed 4 Contact Parazero support Flickering Yellow x1 NA RC channel is disconnected or in active state 1 Check RC is on 2 Check that RC button is not pressed 3 Check RC is paired to device Flickering Yellow x2 NA System is not level Check system is positioned on a leveled surface Flickering Y...

Page 19: ...em is positioned on a level surface Solid Red Triggered Repeating beeping pattern with increasing frequency System was triggered and parachute deployed None Flickering Red x3 Repeating 3 beep pattern System battery is low Finish mission and charge system If system is armed it will continue to operate but if power will drop it will stop to function ParaZero Remote Controller RC is an optional add o...

Page 20: ...inateAir LEDs are on Go back to a safety distance of at least 5 meters 8 2 Takeoff When climbing you must climb to approximately 7 meters before the system is armed Climb until you hear a single long beep and the LED is GREEN The system is now armed and ready for activation in case of an emergency 8 3 Before Landing When approaching landing and the drone slowly while keeping it level Three seconds...

Page 21: ...ment analysis 9 2 Repacking the parachute Inspect the parachute and make sure there is no damage to the parachute lines or the main parachute strap Inspect the canister SmartAir connectors and the TerminateAir to make sure that there is no apparent damage If there are tears or other suspected damage please contact us at support parazero com You will require all system components except the Termina...

Page 22: ...d the 2 3 of the right cells under the folded parachute 6 Fold the left and right part of the folded parachute over each other Fold one side to the middle and then fold the other side on top of it It is important to keep the structure of the previous folds Start the folding process from one end and use weights to keep the parachute folded as you move along the length of the parachute ...

Page 23: ...r from the socket in the bottom of canister 9 Place a new Pyro actuator in place according to the above mentioned procedure 10 Place the red base into the bottom of the canister 11 Place all the lines at the bottom of the canister on the red base so that the folded part of the main strap figure 8 shape is put first on the red base and the rest of the lines are placed above it The rest of the main ...

Page 24: ...Tel 972 36885252 30 Dov Hoz Kiryat Ono Israel 5555626 www parazero com Operate Drones Everywhere Safely ...

Reviews: