background image

5

Introduction

Congratulations and thank you for your purchase of this precision Parasound audio
component. The Parasound Zamp v.2 is designed for a wide variety of applications,
including multi-room, multi-zone installations, desktop audio, bedroom or den systems.
The incredible versatility of the Zamp v.2 allows many connection and configuration
options, so please be sure to read this manual thoroughly before you begin installation.

Unpacking

Carefully unpack your Zamp v.2, remove the enclosed AC power cord and the sub-mini
2.5 mm trigger connection plug and wire. Be sure to inspect the unit for any possible
shipping damage. If you notice any, contact your Parasound Dealer immediately. Save the
carton and all of the packing materials in case you ever need to ship your amplifier for
repair. Before you proceed, locate the serial number on the rear panel or underside of the
unit and record it here for future reference:

Serial #_____________________________      Purchase Date  _____________________

Parasound Dealer ____________________        Phone Number _____________________

Installation and Rack Mounting

Install your Zamp v.2 away from heat sources such as heating ducts and radiators. Always
mount the amplifier horizontally.

Its panel dimensions are one rack space high (1 3/4" or 44 mm) by one-half rack space
wide (9 1/2" or 242 mm). It will fit into a standard 19" wide equipment rack when
mounted side-by-side with other Parasound half-width components. Optional accessory
parts are available from Parasound to rack mount the Zamp v.2 by itself or alongside
another Parasound half width unit.

Ventilation Requirements

The Zamp v.2 can generate substantial heat and requires adequate ventilation to prevent
overheating and shut down by its thermal protection circuit. Observe the following
ventilation guidelines when installing the Zamp v.2 in a cabinet or other enclosed area:

1)  If you are not using a ventilation fan, allow few inches on each side and above the
unit. You should never install the Zamp v.2 in an unventilated equipment cabinet with a
door or panel because hot air cannot exhaust adequately.

3)  Do not place the Zamp v.2 on carpeting or any other material that could obstruct
airflow through the ventilation holes in the bottom of its chassis.

4)  Try to avoid stacking the Zamp v.2 tightly between other components because the heat
it produces will not dissipate adequately and may cause overheating of the amplifier and
the other units.

Summary of Contents for Zamp v.2

Page 1: ...1 O W N E R S M A N U A L www parasound com Zamp v 2 Zone Amplifier...

Page 2: ...p v 2 11 Zamp v 2 Specifications 12 Features of the Parasound Zamp v 2 30 Watts Per Channel into 8 Less than 0 06 THD 45 Watts Per Channel into 4 Less than 0 06 THD 60 Watts Mono into 8 10 Amperes Pea...

Page 3: ...This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of...

Page 4: ...ound Products Inc San Francisco CA USA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN 120 V 60 Hz 120 W Inputs Loop Out Level Sens Mono St In Out 12 V Trigger Audio Lift Gnd Auto On Man Z a m p Z o n e A...

Page 5: ...away from heat sources such as heating ducts and radiators Always mount the amplifier horizontally Its panel dimensions are one rack space high 1 3 4 or 44 mm by one half rack space wide 9 1 2 or 242...

Page 6: ...ransverse hole in the terminal s binding post Before inserting the wire twist its strands tightly between your fingers to prevent strays that might cause a short circuit You may want to tin the stripp...

Page 7: ...e front panel In the left position of the Auto On Switch the Zamp v 2 is turned on and off when an audio signal is present at the Left and Right Input jacks When the audio signal ceases the Zamp v 2 w...

Page 8: ...Power Connections and AC Grounding If possible plug your Zamp v 2 into the same AC outlet that powers your accompanying audio components and especially the system controller If you use a different AC...

Page 9: ...If you suspect a problem with your Zamp v 2 first turn the unit off and check all your connections Another component or even a defective hookup cable may be causing the trouble If you hear hum turn of...

Page 10: ...ranty repair contact us and we will advise you of the repair charges before you ship the unit to us The same packing and Return Authorization number requirements apply Important Notice before Shipping...

Page 11: ...lector switch located on the bottom of the unit For 110 120 Vac operation Slide the switch into the position until the section of switch labeled 115 appears through the opening in the chassis For 220...

Page 12: ...second Frequency Response 5 Hz 100 kHz 0 3 dB at 1 watt Total Harmonic Distortion 0 06 at full power 0 03 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Cross...

Page 13: ...13 2001 Parasound Products Inc Rev 2 0 Parasound Products Inc 950 Battery Street San Francisco CA 94111 415 397 7100 FAX 415 397 0144 www parasound com...