background image

Maintaining your HCA-1200II

The HCA-1200II requires no periodic maintenance and has no user serviceable parts inside. Do not remove
the top cover to avoid risk  of electric shock. To keep it clean use only a soft cloth and never use any solvents
or abrasives. Fingerprints may be removed with a soft cloth moistened only with a few drops of water.

The amplifier has corrosion-free gold input  jacks, but each year it is a good idea to twist the input plugs to
preserve perfect signal transfer by removing corrosion which might have accumulated on the connecting
plugs themselves. Make sure the unit  is turned off  while you do this.

Fuse

The HCA-1200II  has one external 10 ampere fuse which may blow as a result of an internal fault condition.
This protects the unit from possible damage to internal parts. Never replace this fuse with a  larger value.
Substitution of a larger fuse may create serious stress or damage to internal parts and will void your war-
ranty.

In Case of Trouble

lf you suspect a problem with this unit, first recheck  all your connections. If only one channel is inoperative,
the trouble may be caused by another component or even a defective hookup cable. However, if the same
channel is at fault when you reverse the Left and Right channel pair cables to your HCA-1200II (turn it off
before moving wires), it may indicate trouble within the power amplifier itself. We suggest you contact your
authorized Parasound Dealer or Installer, or call Parasound Technical Service if you suspect a problem.  We
may be able to suggest other diagnostic tests you can easily perform yourself and which will save you a lot
of trouble.

If it is determined that the HCA-1200II should be returned to Parasound for inspection and possible servic-
ing, you must first call or write to obtain a Return Authorization number. You will be asked to repack the unit
in its original styrofoam packing and both of its cardboard cartons for proper protection in transit. We will
give you shipping instructions.

Units that arrive without the correct Return Authorization number, without a suitable shipping carton or
evidence of improper internal packing or collect will be refused. We cannot accept collect shipments. After
repair under warranty, the unit will be returned to you prepaid. If we found no problem with the unit, we will
return the unit with collect charges for return shipping charges.

- 7 -

Summary of Contents for HCA-1200II

Page 1: ...CA1200II has greater operational flexibility and power than most other power amplifiers you may have encountered so please take a few moment to read these instructions thoroughly so you may fully unde...

Page 2: ...Input jacks 2 Input level controls 3 Mono bridge mode selector switch 4 Channels 1 2 4 8 speaker terminals 5 Main Fuse 6 AC cord connector Front Panel 1 Power Switch 2 Standby Operation LEDs 3 Curren...

Page 3: ...level sources placed too close to your HCA 1200II might pick up some hum radiated from its enormous power supply Rack Mounting your HCA 1200II Your HCA 1200II can be mounted in a space slightly highe...

Page 4: ...power amplifier terminals Polarity is marked separately for both stereo and bridged connections Mono Speaker Connection When you bridge the left and right channels you connect your speakers to the co...

Page 5: ...f position The HCA 1200II includes an audiophile grade detachable AC cord We recommend that you use only this cord and try to make direct connection to the AC wall outlet Connection to a flimsy extens...

Page 6: ...ndicate overload of the power supply just before the onset audible distortion In virtually all imaginable listening situations these LEDs will rarely illuminate Level Controls Each channel has a separ...

Page 7: ...e the trouble may be caused by another component or even a defective hookup cable However if the same channel is at fault when you reverse the Left and Right channel pair cables to your HCA 1200II tur...

Page 8: ...s peak Slew Rate 130V second Frequency Response 8Hz 150kHz 0 3dB at 1 watt Total Harmonic Distortion 0 06 at full power 0 03 typical levels TIM Unmeasurable IM Distortion 0 04 Dynamic Headroom 2dB lnt...

Page 9: ...istors Output transistors direct coupled to speakers without LRC network DC servo direct coupled audio circuits with 3Hz roll off Linear tracking instantaneous acting DC servos High bias Class AB oper...

Page 10: ...ine John has published definitive articles on advanced circuit design and the influence of different capacitor types on the reproduction of music He designed the Denneson JC 80 preamplifier Symmetry e...

Page 11: ...ng or operation with load impedances contrary to printed instructions This warranty applies only to units used in residential non commercial situations The warran tor assumes no liability for property...

Page 12: ...feel the resulting sonic improvements are significant and justified However to insure safe and reliable operation it is very important that the amplifier has plenty of ventila tion to prevent overheat...

Reviews: