High Pass Crossover  

The 200 Pre High Pass Crossover for the Main Outputs allows you to block low frequencies from going to your 
main L and R speakers.  This can be particularly useful if you are using small speakers (typically with woofers 
that are 6.5”/165

 

mm or smaller) and you have a subwoofer.  The most common settings are between 50

 

Hz 

and 80

 

Hz.  If you are not using a subwoofer you will get better results by turning the 200 Pre High Pass 

Crossover off or setting it at 40

 

Hz or lower.  If you want your L and R speakers to operate full range with no 

frequencies blocked set the High Pass crossover switch to the Off position. 

 

Subwoofer Setup 

 

For proper subwoofer operation you must first pick the subwoofer output most appropriate for your system and 
adjust your subwoofers built in crossover as needed.  After picking the correct crossover you must setup the 
subwoofer level.

 

 

>80Hz Subwoofer #1 Output (Low Pass) 

If you are connecting your subwoofer to the 200 Pre’s “>80Hz” Sub output then you should turn off the 
crossover built into your subwoofer.  Using both the sub’s and 200 Pre’s crossovers will result in low output 
caused by “double-filtering.”  Most powered subwoofers have a switch that’s typically labelled “Bypass”, “LFE” 
or simply “Crossover Off.”  If your subwoofer’s crossover cannot be switched off, set it to its highest frequency.   

 
 

Full Range Subwoofer #2 Output 

If you are connecting your subwoofer to the 200 Pre’s “Full Range” Sub output then you must leave your 
subwoofer’s crossover engaged. 
 
 

Subwoofer Level Setup

 

To set the proper subwoofer level, start with the 200 Pre’s subwoofer level control set to its flat (0

 

dB) position 

and play a variety of music.  Adjust the level control on your subwoofer until the bass level sounds balanced in 
your system.  Now, whenever you want to fine tune your subwoofer level you can simply use the 200 Pre’s 
front panel or remote-control Sub level control instead of walking over to your sub, bending down and reaching 
behind it to adjust its level control. 

 

Using Stereo Subwoofers 

If you have two subwoofers and want them to operate in stereo you can connect them to the Left and Right 
Main Output jacks instead of to the Sub Output jacks which are mono.  In this case you need to set the High 
Pass crossover switch to Off.  With this configuration the 200 Pre Sub Level control and on/off by remote do 
not function. 

 
 
 
 
 
 
 
 

Summary of Contents for 200 Pre

Page 1: ...200 Pre Stereo Preamplifier DAC Owner s Manual...

Page 2: ...rong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat th...

Page 3: ...invoice and store it inside the 200 Pre s carton If the 200 Pre should require warranty repair you will need its original carton and foam packing inserts to ship it Please do not throw away the carto...

Page 4: ...utputs 10 Subwoofer Outputs 10 Fixed Rec Outputs 10 Headphone Jack 10 12 Volt IR and RS 232 Connections 10 High Pass Crossover 11 Subwoofer Setup 11 Front Panel Display and Controls 12 Volume Multifun...

Page 5: ...d any heat producing equipment You should also avoid installing the 200 Pre in an unventilated equipment cabinet or small compartment because hot air created by the other components will not exhaust a...

Page 6: ...Parasound 200 Pre Owner s Manual Page 6...

Page 7: ...Input 2 Input 2 is compatible with any typical analog line level source Input 3 Aux Input 3 is compatible with any typical analog line level source but is shared with the Aux input on the front panel...

Page 8: ...full range The exclusions above are intentional so your surround sound receiver bass management menu settings and volume control function normally when you are listening to surround sound with the Le...

Page 9: ...ical cable It has limited flexibility and if you bend it at a sharp angle you ll impair its ability to transfer the optical signal from your source to the 200 Pre Coax Coaxial The Coax also called S P...

Page 10: ...tions 12 Volt Output Jack The 12V Out is used to turn a power amp or other accessories on and off automatically If your power amplifier is equipped with a 12 volt trigger input connect the included tr...

Page 11: ...oth the sub s and 200 Pre s crossovers will result in low output caused by double filtering Most powered subwoofers have a switch that s typically labelled Bypass LFE or simply Crossover Off If your s...

Page 12: ...hange The knob functions rotate through in this order with each press Input The default function no press of this knob is input selection Rotating it cycles through all of the inputs Stop at the input...

Page 13: ...stics The maximum adjustment is 15dB Volume and The and buttons increase and decrease the volume level Mute Press to mute the audio Pressing a second time will unmute the audio The mute is also turned...

Page 14: ...to the level it was last used at Cancel the Turn On Volume feature 1 Press the Set button 2 Press the Power Off button Now when the 200 Pre turns on the volume will be set to where it was last used M...

Page 15: ...he available names 4 When you have found the name you want press Set again to memorize Repeat steps 1 through 4 for the other inputs Input Level Offset This feature allows you to increase or decrease...

Page 16: ...r amp s stereo mono switch is set to stereo The USB input is not playing audio from my Computer Look in the sounds options of your computer and select PARASOUND as the output Ensure the USB cable is c...

Page 17: ...Warranty Unit is not eligible for repair under the terms of the Parasound warranty if 1 Unit was not purchased from a Parasound Authorized Dealer 2 You do not have the original bill of sale or sales...

Page 18: ...ighted 90dB input shorted unweighted S N Ratio Digital Inputs 100dB input shorted IHF A weighted 90dB input shorted unweighted DAC IC Burr Brown PCM1798 DAC Maximum Sampling Rates PCM only USB 96kHz 2...

Page 19: ...Parasound 200 Pre Owner s Manual Page 19...

Page 20: ...Parasound 200 Pre Owner s Manual Page 20 Parasound Products Inc 2250 McKinnon Ave San Francisco CA 94124 Customer Service Tech Support 415 397 7100 www parasound com...

Reviews: