3.  The pressure regulator supplied with the appliance is to be fitted to the 

gas supply line as close as practical to the heater (natural gas models 
only). The heater must be connected with an AGA approved 15mm 
diameter braided stainless steel hose. 

 

4.  The heater needs to be wired to the main electrical supply by a licensed 

electrician and each heater should have its own isolation switch. 

 

5.  When the installation is complete test the gas line for soundness with a 

manometer then test fire the heater and check that the gas pressure is 
correct. 

 

6.  If the heater cannot be adjusted to operate correctly contact the supplier 

or your nearest Parasol Heaters Australia office. 

 

O

O

P

P

E

E

R

R

A

A

T

T

I

I

N

N

G

G

 

 

I

I

N

N

S

S

T

T

R

R

U

U

C

C

T

T

I

I

O

O

N

N

S

S

 

 

 

To light the heater

, turn the power on. The unit has a 15 second spark for 

ignition time. If it does not light by the end of this time you will need to turn the 
power off and wait for 5 minutes and then turn the power back on again. 
 

To turn the heater off

, turn the power off. 

 
This heater should burn with a blue flame and the tiles should glow red. If the 
heater burns with a long yellow flame or starts to soot turn off and contact a 
qualified service person. 
 
 

We recommend that this heater be serviced every 12 months. 

Servicing shall be carried out only by authorised personnel. 

Summary of Contents for SunPhase 16E LP

Page 1: ...Created on 12 08 2009 11 58 24 PM Installation Operating Instructions SunPhase Radiant Heater M MO OD DE EL L N No o S Su un nP Ph ha as se e 2 25 5E E L LP P N NG G S Su un nP Ph ha as se e 1 16 6E E...

Page 2: ...R RM MA AT TI IO ON N R RE EG GA AR RD DI IN NG G U UN NI IT T 4 D DI IM ME EN NS SI IO ON NS S a an nd d W WI IR RI IN NG G 5 U UN NI IT T C CL LE EA AR RA AN NC CE E 6 P PR RI IO OR R T TO O I IN NS...

Page 3: ...dels available in both Natural Gas and LPG This unit has electronic ignition Installation is made easy with wall plate fixing and removable mounting bracket All heaters come with a 12 month parts only...

Page 4: ...hould not be hung from the appliance or placed on or near the appliance o Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance o I...

Page 5: ...llation Operating Instructions o D DI IM ME EN NS SI IO ON NS S a an nd d W WI IR RI IN NG G Model dimensions are shown on the line drawings The gas connection is located at the bottom left hand corne...

Page 6: ...akage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one of the following In the case of balconies at le...

Page 7: ...appliance must be a minimum of 1 8m above floor level Please note If installed outdoors this appliance shall only be used in an above ground open air situation with natural ventilation without stagna...

Page 8: ...bracket fixed to the heater must not be modified in any way 2 For fixing to a wall remove the wall plate from the mounting bracket as detailed below Undo the nut on the J bolt and then remove the bolt...

Page 9: ...for soundness with a manometer then test fire the heater and check that the gas pressure is correct 6 If the heater cannot be adjusted to operate correctly contact the supplier or your nearest Paraso...

Page 10: ...ck electrode for spark Make sure electrode assembly has not been moved in transportation Unit lights but then goes out Check that polarity is correct Check that sense wire is connected properly Check...

Page 11: ...purchase parts only subject to installation in accordance with conditions detailed on page 7 o In the event of the unit having to be returned for repair it must be forwarded to 12 Yiannis Court Sprin...