Offboard Wiring

9V pad to DC jack positive lug (or battery clip +)

GND pad to DC jack negative  (or battery clip -)

OUT pad to output jack Tip

GND pad to output jack sleeve

LFO sw pads to momentary SPST switch or button 

(which wire goes

to which switch lug doesn't matter)

Optional sequencer on/off indicator LED

If you want an LED to indicate when the LFO is running (like I have 
in my complete build, combined inside the LFO button) this is how 
you hook it up.

Connect the square ”LFO SW” pad to a current limiting resistor

LED cathode/negative side to the resistor

LED anode/positive side to DC jack (or battery clip) po