background image

14

OPTIONAL EQUALIZER VALVE & FLOAT VALVE INSTALLATION

SOMETIMES REQUIRED ON COMMERCIAL POOLS.

 

DANGER

DEATH or SERIOUS INJURY will result if this product is not installed 
and used correctly.

OPTIONAL EQUALIZER VALVE INSTALLATION Fig. 14
1. Ensure the O-ring is in the retainer groove 

of the equalizer valve (Pentair part #08655-
0017) that comes with the float valve. Check 
for operation of the equalizer mechanism.

2. Install equalizer valve by threading valve into 

the skimmer equalizer line port as shown.

3. Be sure that pump port in bottom of skimmer 

is not blocked by trimmer plate and that the 
trimmer plate on the  bottom of the float 
valve is moved as far as possible to the side 
of the valve.

OPTIONAL FLOAT VALVE INSTALLATION 
(Pentair part #08650-0079)
1. Install the adapter ring on the ledge near the bottom of the skimmer.
2. Place float valve into bottom of skimmer. Press to seat the O-ring in place.
3. To increase water flow through the valve, slide the trimmer plate to uncover 

the hole in the bottom of the valve. To decrease flow, slide the trimmer plate 
to cover the hole in the bottom of the valve.

OPERATION
When the water level drops below the weir of the skimmer, the water level in the skimmer will drop until 
the float valve closes. The equalizer valve will open at this time, allowing water to flow to the pump from 
the equalizer line. After the pump has been turned off, and the water level is raised to the appropriate 
level for good skimming action, the equalizer valve will close and the float valve will automatically open. 
Normal operation will resume when the pump is turned back on.

FLOAT VALVE

O-RING

TRIMMER

PLATE

SCREW

MAINTENANCE & WINTERIZING

•  Weir: Periodically check weir for free operation. Replace if damaged or worn.
•  Strainer Basket: Check strainer basket every few days for accumulated leaves, debris, etc. Empty 

basket and flush optional fine mesh bag as required. Reset float valve if it closed.

•  Float Valve: Optional: Periodically check that float valve is operating freely and is not waterlogged. 

If necessary, tighten trimmer plate pivot screw to maintain desired flow balance.

•  Equalizer Valve (Public Pool Models): Inspect for wear or deterioration. Make sure that screw is 

tight in equalizer valve body. If you can detect flow through equalizer with float valve open, replace 
check valve.

• Equalizer (Wall) Fittings: Daily check that Listed wall suction 
fittings are correctly installed and that covers are tight to fittings. 
Visually inspect for debris blocking cover. Remove any debris.  

•  Water Level: Maintain water level at least equal to the center of the weir door for proper operation. 

Adjust trimmer plate as necessary if equipped.

 

WARNING

OPTIONAL

EQUALIZER LINE

OPTIONAL

FLOAT VALVE

TO PUMP

EQUALIZER VALVE

Fig. 14
Start up

Summary of Contents for Paraskim

Page 1: ...CRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE WARNING Paraskim and Paraskim V must be installed in accordance with Paramount s written instruction manual and in conformity with applicable Federal...

Page 2: ...and spa pumps produce high levels of suction and move high volumes of water which can cause death or serious injury if a person comes in close proximity to pool or spa drains Keep clear of pool and s...

Page 3: ...when designing and installing a proper filtration system Properly bond grounded pumps time clocks switches and any other metal in or near water This is required to address Electrical Shock Hazards De...

Page 4: ...long pipe runs in which friction can reduce flow and pressure refer to a friction flow chart for proper pipe sizes 5 When planning location of skimmers on one and two skimmer outdoor pools locate skim...

Page 5: ...r 2 skimmers Using sweep 90 fittings or two 45 fittings in place of a single 90 is more efficient 4 For pressure testing seal off any used ports Over tightening the threaded plugs may result in failur...

Page 6: ...PVC valve controlled line from the return manifold to the bottom 1 port of the skimmer This valve is set during normal operation of the skimmer to use about 8 10 GPM through the Dual venturi nozzle N...

Page 7: ...page 18 1 The side port on the skimmer will need to be drilled with a 5 8 bit and the tube adapter fitting installed in the end of the pipe before it is connected to the skimmer socket Fig 4 2 Plumb a...

Page 8: ...PVC and cap the end to prevent gunite from entering An optional float valve assembly will be needed for this option Float valve purchased separately Install an equalizer fitting that conforms to ANSI...

Page 9: ...e 2 skimmer venturi return line Fig 9 2 Before plastering or applying the finish to the pool cut the 2 return line 3 behind the gunite surface and glue the return guard fitting to the 2 pipe so it wil...

Page 10: ...or hack saw blade the extra deck ring slats that protrude down and block the skimmer throat The throat should be completely open when the deck ring is set at desired deck thickness Fig 11 GUNITE VENTU...

Page 11: ...ell OPTIONAL The skimmer may be set after the concrete shell is shot Notch the concrete at the top of the pool wall where skimmer is to be set and cut a 8 diameter hole for the venturi return guard to...

Page 12: ...mount return guard FAILURE TO INSTALL THE RETURN GUARD FITTING AND RETURN GUARD COVER CAN RESULT IN SERIOUS INJURY OR DEATH WARNING 3 After the interior finish is applied attach the return guard cove...

Page 13: ...tom port in the event that winterizing is necessary NOTICE 3 The venturi skimmer may be operated simultaneously with the normal skimmer functioning or the suction from the pump may be shut off or not...

Page 14: ...n at this time allowing water to flow to the pump from the equalizer line After the pump has been turned off and the water level is raised to the appropriate level for good skimming action the equaliz...

Page 15: ...equipment Different methods are used depending on regional conditions It is the pool operator s responsibility to ensure all components of the pool and pool equipment are protected from the most sever...

Page 16: ...l water level to recommended height 2 Check ozone meter valve setting With ozone return some air expected TROUBLESHOOTING 11 Pour some antifreeze down the pipe and into the skimmer for added freeze pr...

Page 17: ...52 4570 XX Deck lid 4 005 702 6000 XX Notched deck ring 5 005 152 2207 00 Basket 6 005 702 9100 00 Trimmer plate assembly 7 004 152 4517 00 Mesh bag 600 Micron 8 004 252 4745 00 Optional 2 winterizing...

Page 18: ...ction feed tubing kit 9 005 702 9205 XX Return guard assembly standard 10 004 152 4517 00 Mesh bag 600 Micron 11 004 552 5452 00 Optional small Nozzle Tool 12 005 702 9210 XX Optional return guard ass...

Page 19: ...M V WITH VENTURI SHOWN WITHOUT BASKET DUAL PRESSURE VENTURI NOZZLE TOP OF BEAM TOP OF BEAM WEIR DOOR RETURN GUARD WEIR DOOR OPTIONAL OZONE INJECTION FEED TUBE DUAL PRESSURE VENTURI NOZZLE BASKET BASKE...

Page 20: ...20...

Reviews: