1. 

Remove Plaster Cap from Fountain and blow out

the lines to remove any construction debris that may
be in the pipes. 

2.

Set the end of the fountain shaft with the stopper

down over the fountain body and mark the water level
on the shaft.(See Figure 17)

3.

Transfer the water level mark to the other two

shafts. (See Figure 18)

4.

Using the longest 53-inch shaft, measure and mark

an additional 13¼ inches away from the stopper end.
(See Figure 18)

5.

Using the 45-inch shaft, measure and mark an

additional 5¾ inches away from the stopper end. (See
Figure 18)

6.

Using the 40-inch shaft, measure and mark an

additional ¾ inches away from the stopper end. (See
Figure 18)

7.

Cut all three fountains at the farthest mark from the

stopper end.

8.

Insert each fountain shaft through a fountain

retainer so the bottom of the fountain retainer is next
to the stopper that is glued to the shaft. (See Figure
19)

9. Umbrella Fountain 

(See Figure 20)

a. Select the longest fountain shaft.
b. Put a small dab of PVC glue on the outside of the
threaded insert and press into the shaft opposite the
stopper end.
c. Glue the umbrella end-cap over the outside of the
fountain shaft, or same end as the threaded insert.
d. Wipe off any excess glue.
e. Thread the umbrella into the threaded insert until
you have a 1/16 inch gap. When installed balance
flow and gap to desired effect.

10. Flower Fountain 

(See Figure 21)

a. Select the medium length fountain shaft

FOUNTAIN STARTUP INSTRUCTIONS

 

 

 

:$7(5/(9(/

&87/,1(

&87/,1(

&87/,1(

67233(5

WATERLINE

MARK AT
WATER LINE 

 

To Top Of

Fountain
Waterlevel

Cut Marks

9"

10"

11"

8"

7"

6" OR 

LESS

Fig. 17

Fig. 18

Fig. 19  

Summary of Contents for PARASCOPE

Page 1: ...T oll Free 1 800 621 5886 Phone 480 893 7607 Fax 480 753 3397 Paramount 1Paramount com www 1Paramount com 004 027 8740 00 REV110811 TELESCOPING WATER FEATURE INSTALLATION MANUAL PLEASE READ THE INSTA...

Page 2: ...rench to accommodate the Fountain Housing Assembly 7 Each Fountain must be fed by a separate 1 Sch 40 pipe and gate valve to allow each fountain to be adjusted separately Glue the Fountain Housing to...

Page 3: ...n Housing Shaft at the marker indicating your water depth to minimize the need for digging a deep hole for the shaft however this step is optional See Figure 6 4 Cut another 2 pipe to this same length...

Page 4: ...2 Pressure test the Fountain Housing to code pressure to remain on system until plaster 13 Backfill the plumbing trenches with dirt to maintain its vertical alignment If there is a vertical trench in...

Page 5: ...untains water heights may be adjusted individually Paramount Fountain Manifold Plumbing w Wall Returns No Infloor System See Figure 10 1 Each Fountain that is installed should be run with its own 1 ga...

Page 6: ...s 2 way and 3 way valves do not easily make minor adjustments and may damage the Fountainheads 5 A 2 way ball valve must be plumbed between the tee to the last Fountain and the wall returns so the Fou...

Page 7: ...rrel and 3 deep inside the riser pipe Push the body into the pipe until the shoulder hits the top edge of the pipe 5 Let fumes vent for 30 minutes then replace all body caps See Figure 15 PLASTERING T...

Page 8: ...est mark from the stopper end 8 Insert each fountain shaft through a fountain retainer so the bottom of the fountain retainer is next to the stopper that is glued to the shaft See Figure 19 9 Umbrella...

Page 9: ...ss glue 11 Bubbler Fountain See Figure 22 a Select the shortest length fountain shaft b Glue the bubbler cap over the end of the fountain shaft opposite the stopper c Wipe off any excess glue 12 Insta...

Page 10: ...ella Top 6 Umbrella Cap 7 Umbrella Threaded Insert 8 Retainer 9 Bubbler Shaft 40 10 Flower Shaft 45 11 Umbrella Shaft 53 12 004 627 5452 00 Fountain Tool 13 Plaster Cap 14 Body 15 005 059 2385 XX Para...

Page 11: ...el fono sin costo 1 800 621 5886 T el fono 480 893 7607 Fax 480 753 3397 Paramount 1Paramount com www 1Paramount com 004 027 8740 00 REV090111 CARACTER STICA TELESC PICA DEL AGUA MANUAL DE INSTALACI...

Page 12: ...tuber a de alimentaci n de modo que quede empotrada 8 Pegue la tapa al elevador Paramount para probar la presi n Ver Figura 3 9 Pruebe la presi n de la carcasa de la fuente al c digo la presi n que qu...

Page 13: ...ARTE TRASERA DEL ANAQUEL 6 M NIMO DESDE LA PARTE FRONTAL DEL ANAQUEL Fig 5 NIVEL DE AGUA 2 2 PROFUNDIDAD PLANEADA DE AGUA Waterlevel Waterlevel Cut Marks Cut Marks 9 9 10 10 11 11 12 12 13 13 14 14 15...

Page 14: ...l mortero 13 Rellene las fosas de plomer a con cascajo para mantener la alineaci n vertical Si hay un foso vertical en la pared lateral del estanque apisone cascajo alrededor del extremo inferior de l...

Page 15: ...ula de compuerta de 1 para permitir el ajuste del flujo de agua a cada fuente de manera individual para el efecto deseado 2 NO coloque una v lvula de dos o tres v as en lugar de la v lvula de compuert...

Page 16: ...instalar una v lvula de globo de dos v as entre la T a la ltima fuente y los retornos de muro de modo que las alturas del agua de las fuentes puedan ajustarse de manera individual L NEADE1 A LAFUENTE...

Page 17: ...o elevador Empuje el cuerpo dentro del tub hasta que el hombro toque el borde superior del tubo 5 Deje que los vapores se ventilen 30 minutos y luego reemplace todos las tapas del cuerpo Ver Figura 15...

Page 18: ...sujetador hasta que el fondo del sujetador de la fuente est junto al tope que est pegado al tiro Ver Figura 19 9 Aspersor para fuente sombrilla Ver Figura 20 a Seleccione el tiro de fuente m s largo...

Page 19: ...tope c Limpie el exceso de adhesivo 11 Aspersor burbujeador para fuente Ver Figura 22 a Seleccione el tiro de fuente m s corto b Adhiera el aspersor burbujeante al extremo del tiro opuesto al tope c...

Page 20: ...a 7 Extremo con roscado de la sombrilla 8 Sujetador 9 Tiro burbujeador de 40 101 cm 10 Tiro de flor de 45 114 cm 11 Tiro de sombrilla de 53 134 cm 12 004 627 5452 00 Herramienta para fuente 13 Tapa de...