background image

1.    While holding the new float, twist sleeve 

counter clockwise until it comes out of the 

float. 

2.   Turn float over and re-thread on sleeve with 

flat side up. Be careful not to cross-thread 

(Fig. 12).

3.   Compare the float height on the sleeve to the 

old float. The new style float will need to be 

approximately 5/8” lower on the sleeve to 

achieve a similar water level (Fig. 13).

4.   Install in the housing and turn on the water 

supply.

5.    If the float is off, shut off the water and re-

move the float and turn in the direction in-

dicated on the flat side of the float to raise 

the water level 1/8”, one half turn, or 2 

posi-clicks. Follow the arrows on the float  

(Fig. 14).

6.   If the float is on, shut off the water and re-

move the float and turn in the direction in-

dicated on the flat side of the float to raise 

the water level 1/8”, one half turn, or two 

(2) posi-clicks. Follow the arrows on the float 

(Fig. 14).

7.   Repeat steps 5a or 5b until water level is 

matched.

8.   Check pool level after a few days to verify 

correct set level.

Use New Float in Old Tank

Fig. 12

Fig. 13

Fig. 14

Arrows

USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS

6

Summary of Contents for Paralevel

Page 1: ...Paramount com Paralevel Automatic Water Leveler Start Up Manual Contents Overview 1 Start Up 2 Winterization 4 Identify Paralevel Model 5 Use New Float in Old Tank 6 Replacement Parts 7 004 027 8886 0...

Page 2: ...mbed with or pipe The Paralevel can also be plumbed with 11 2 pipe for overflow protection Paralevel Layout Design Criteria 1 Paralevel should be level and plumb 2 The Paralevel main housing is engrav...

Page 3: ...that the Retainer Ring is installed properly in the Retainer Nut The retaining piece with raised rounded center is inserted facing the top of the retainer nut Fig 2 Use Removal Tool to install Nut Ret...

Page 4: ...r feature as part of its smart sensing The Paralevel works best at full pressure Fill the pool until the water level is just below center of tile with less than 1 left to fill Shut off and remove all...

Page 5: ...ut Next using the removal tool 10 on the Paralevel exploded parts diagram page 6 remove the Retainer Nut and Retainer Ring 19 and 20 Next using a 3 8 inch socket wrench extension remove the Flow Plug...

Page 6: ...Seal and Main seal 1 and 3 on the winterizing kit exploded parts diagram page 7 over this opening It is recommend that the disconnected water line at the house be taped shut or sealed when disconnect...

Page 7: ...the water and re move the float and turn in the direction in dicated on the flat side of the float to raise the water level 1 8 one half turn or 2 posi clicks Follow the arrows on the float Fig 14 6...

Page 8: ...w Plug Cap Seal 18 Part of Item 24 O Ring 2 020 EP70 Seal Plug 19 Retainer Nut O Ring 2 020 EP70 20 Retainer Ring 8 005 252 1541 00 Extension Kit 21 Adjuster Sleeve 9 004 552 5452 00 Tool 22 Float Bod...

Page 9: ...p Seal 18 Part of Item 24 O Ring 2 020 EP70 Seal Plug 19 Retainer Nut O Ring 2 020 EP70 20 Retainer Ring 8 Extension Kit 21 Adjuster Sleeve 9 004 552 5452 00 Tool 22 Float Body 10 004 760 2921 00 Star...

Page 10: ...05 760 2901 00 Winterization Pressure Test Kit 1 1 2 NPT Cap 2 Main Seal 3 Cap Seal 4 Seal Plug 5 O Ring 2 020 EP70 Paralevel Winterizing Pressure Test Kit 005 760 2911 00 1 2 3 4 5 9 USE ONLY PARAMOU...

Page 11: ...USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS 10...

Page 12: ...stries Inc 2023 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third partie...

Reviews: