background image

MDX-R3 FIBERGLASS WINTERIZATION

WITH CANISTER

WITHOUT CANISTER

If vacuum relief suction outlets are located below freeze 

line skip steps 1 and 2. 

1.

   Remove grate from second suction and install a  

13-¾ blow through plug and blow line to achieve 

airlock.

2.

   If 3rd suction line is installed remove grate, install 

13-¾ blow-through plug and blow line to achieve 

airlock.

3.

  Go to canister instructions step 1 - 5 below.

4.

   If vent tube is installed, install blow through plug 

and blow line to achieve airlock. Repeat vacuum out 

canister. Then complete canister step 5.

If vacuum relief suction outlets are located below freeze 

line skip steps 1 and 2. 

1.

   Remove grate from second suction and install  

13-¾ blow through plug and blow line to achieve 

airlock.

2.

   If 3rd suction line is installed remove grate, install 

13-¾ blow-through plug and blow line to achieve 

airlock.

3.

   If vent line is installed in main suction line, plug vent 

line and install blow through plug in pump inlet and 

blow line to achieve airlock.

4.

  Lastly, blow vent line to achieve airlock.

VENT TUBE WARNING LABELS 

Included in each MDX-R3 are two warning labels that 
need to be placed on the pool equipment if the pool is 
to be winterized and has a vent tube on any of the drains 
plumbed on the pool.  Attach the smaller label to the vent 
pipe where it terminates to atmosphere. (See Fig. 9)

Attach the larger label to the control panel next to the 
controller for the pump with the vent tube plumbed to it.
(See Fig. 10)

Fig. 9

Fig. 10

WARNING

When starting pool after winterization, remove plug 

from atmospheric vent pipe before energizing pool 

pump(s)!

Test vent by blocking drain. Air should enter the pipe 

and cause the pump to cavitate releasing the suction on 

the drain block.

AveRtIssemeNt 

Lors du démarrage de la piscine après l’hiver, retirez le 

bouchon du tuyau de ventilation atmosphérique avant 

de mettre la pompe (s) de la piscine en marche!

Testez la ventilation en bloquant le drain. L’air doit entrer 

dans le tube et provoquer la cavitation de la pompe et 

relâcher l’aspiration sur le bloc de drainage.

001-025-8216-00   REV 051314

WARNING

High Suction Atmospheric Vent!

Do not operate pool pump(s) with this pipe plugged!

If necessary to plug vent to winterize the pool do not 

restart pool until plug is removed 

AveRtIssemeNt 

Ventilation atmosphérique à grande succion!

Ne pas faire fonctionner la pompe (s) de la piscine 

avec un bouchon dans ce tuyau!

S’il est nécessaire mettre un bouchon pour hiverner 

la piscine, ne pas redémarrer la piscine jusqu’à ce 

que le bouchon soit enlevé.

001-025-8215-00 REV 043014

Summary of Contents for MDX-R3

Page 1: ...R USE ON FLOOR Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ANSI APSP 16 2011 Compliant with ANSI APSP 7 2006 WARNING MDX R3 and SDX2 must be installed in accordance...

Page 2: ...perly secured or missing because these conditions increase the chance of death or serious injury from entrapment If a drain cover is discovered damaged cracked broken loose clogged not properly secure...

Page 3: ...ety begins with a professional design that includes a quality suction system installed by a certified contractor Certified builders will address the following issues when designing and installing a pr...

Page 4: ...tion outlet being completely blocked the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system MDX R3 and SDX2 m...

Page 5: ...S FOR SUCTION PLUMBING PER LOCAL CODE ENLARGED SUCTION ELEMENT METHOD 1 WITH DECK CANISTER AND MV FUSE IF NOT USING HYDROSTAT PLUG 50mm PORT 50mm SDX 2ND SUCTION OUTLET TO PUMP SKIMMER BYPASS 50mm TRU...

Page 6: ...wn Note Canister requires 40mm equalizer line through pool wall Not Shown ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 2 PORT SDX 2ND SUCTION OUTLET 2 1 2 2 1 2 TO PUMP TRUNK LINE MUST BE SIZE...

Page 7: ...DX2 drain Additional SDX2 drain may be used 2 For Fiberglass Wall Cut one 4 5 11 43 cm hole using a 4 5 11 43 cm hole saw 3 Install the SDX2 Bulkhead Fitting with the UP arrow located at the top Fig 3...

Page 8: ...ithout over tightening 5 Align the SDX2 Cover with the SDX2 Support holes 6 Install three 3 security screws through the SDX2 cover Secure the screws without over tightening Fig 5 Fig 6 Fiberglass Shel...

Page 9: ...is where the gasket will seal Fig 7 2 Glue gaskets to the face of the sump with RTV Silicon glue Be sure to line up all gasket holes with the corresponding hole in the sump Fig 8 TO POOL WALL SCREW H...

Page 10: ...that need to be placed on the pool equipment if the pool is to be winterized and has a vent tube on any of the drains plumbed on the pool Attach the smaller label to the vent pipe where it terminates...

Page 11: ...Coupler Reducer 4 X 2 3 005 282 0842 00 Screw Pack Fiber 19 pc 17 004 182 2212 XX SDX2 High Flow Safety Drain Fiberglass 2 pk XX Color Code 18 005 252 0821 00 Screw 10 X 1 1 4 TORX W PIN SS B 12 pcs...

Page 12: ......

Reviews: