12
Leak Check
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all fire pit and light valves are OFF.
5. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak .
1. Turn cylinder valve OFF.
2. If leak is at hose/ regulator connection: tighten connection and perform another leak test. If bubbles
continue appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/ cylinder valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be
returned to cylinder’s place of purchase.
e
r
u
c
e
s
e
r
a
s
n
o
i
t
c
e
n
n
o
c
e
h
t
,
n
o
i
t
c
e
n
n
o
c
y
n
a
t
a
r
a
e
p
p
a
s
e
l
b
b
u
b
O
N
f
I
.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test.
Complete installation.
Regulator / Cylinder
connection
Hose
/
Regulator
connection
WARNING
Leak Test
* Perform all leak tests outdoors.
* Extinguish all open flames.
* NEVER leak test when smoking.
* Do not use the fire pit until all connections have been
leak tested and do not leak.