14
1” BYPASS
LINE
FILTER
PUMP
BALANCING
VALVE
FROM
SKIMMER
FROM
MAIN
DRAIN
BALANCING
VALVE
BACKWASHING
VALVE
CHECK
VALVE
HEATER
WATER
VALVE
HEATERS
When installing a heater on the pool, a 1" PIPE OR GATE VALVE BY-PASS TO PARTIALLY DIRECT WATER AROUND THE
HEATER IS NECESSARY. This allows part of the water through the heater for heating but limits the head loss created when
all the water is directed through the heater. THE IN-FLOOR SYSTEM MAY NOT FUNCTION PROPERLY WITHOUT THIS
BY-PASS.
NOTE: MULTI-SPEED PUMPS AND HEATERS
& HEAT PUMP
When plumbed with a bypass the heater or heat pump may
not fire with pump running on the lowest speed.
CHECK
VALVE
IMPORTANT
MANUAL
1” BYPASS
LINE
1 1/2 INCH
GATE VALVE
HEAT PUMP
Heat pumps must have a minimum by-pass or 1" pipe or a
1 ½” with a gate valve for adjustment. The gate valve must
be set with a temperature probe to factory specs for heat
rise.
SOLAR SYSTEMS NOT USED
PLUMBING HEATERS