INSTALLATION INSTRUCTIONS
For applications which must comply to sanitation requirements under NSF NO.4 STANDARD.
Under the NSF No. 4 Standard, the models Theater Pop-12 and Theater Pop-16 are defined as other than
portable when used on counter or table tops. This machine must either be mounted on legs to provide a
minimum of four inches of unobstructed space underneath, or must be sealed to the counter or table top.
Option 1: MOUNTING ON LEGS
Order GMI Part No. 16042 (Optional Legs kit). Follow the instructions for installation as
included in the kit.
Option 2: SEALING TO THE COUNTER
1. Remove the cleanout tray and drawer.
2. Remove the terminal box covers.
3. Lay the machine on it front side (doors on top) on a protective pad.
4. Use a ¼” drill to remove the rivet heads and pull off the feet.
5. Set the machine upright and position where it is intended to be used.
6. Apply a bead of NSF accepted RTV sealant along the bottom edges of the machine.
7. Re-assemble the terminal box covers and replace the cleanout tray and drawer.
7