Replacement of the Micro Switch
1. Repeat operations 1-3 for removal of gas control.
2. Pull off the cable connections from the switch.
3. Remove the two screws holding the switch in place and lift away the switch, replace in reverse
order.
4. Turn on the gas supply, check for operation of switch.
Replacement of the Thermocouple
1. Repeat operations 1-13 for removal of gas control.
2. Pull off the cable connections from the switch..
3. Replace in reverse order.
4. Turn on the gas supply, check for soundness and re- commission.
Replacement of the Pilot Injector
1. Undo the pilot tube nut at the pilot bracket.
2. Pull the pipe gently back taking care not to damage.
3. Remove the pilot injector from inside the pilot bracket.
4. Clean or replace in reverse order, turn on the gas supply, check for soundness and re-
commission.
Replacement of the Spark Electrode
1. Remove the cable from the electrode connection.
2. Undo the electrode nut at the pilot bracket.
3. Remove the electrode carefully.
4. Clean or replace in reverse order, and re- commission.
When ordering parts quote 'PARAGON FOCUS RS
'
and the serial number of the fire, which can be
found on the data badge which is located on the appliance remove decorative trim for access.