background image

UIM1-A2-GZ40-00

August 2005

3

Installing the MUM in an IP DSLAM chassis.

The 12000E is a fourteen slot chassis; slots 1–12 are reserved for access modules 
and slots U1 and U2 are reserved for Multiplexer Uplink Modules (MUMs). The 
4000E is a five slot chassis; slots 1–4 are reserved for access modules and slot U1 
is reserved for a MUM.

Procedure

To install a MUM:

1. Align the MUM with the slot module guides of the chosen slot for installation 

(either slot U1 or U2 on the 12000E or slot U1 on the 4000E).

2. Slide the MUM carefully but firmly into the chassis until it is fully seated. 

3. Tighten the fastening screws on the MUM faceplate.

4. Verify that the PWR (Power) LED on the MUM faceplate is illuminated.

Installing the UIM in a Mini DSLAM

Caution:

Disconnect all power sources from the Mini DSLAM before installing the 
UIM.

Procedure

To install a UIM in a Mini DSLAM:

1. Remove the eight screws securing the Mini DSLAM chassis and carefully lift 

off the chassis cover. Set the screws aside.

2. Select a port on the Mini DSLAM for UIM installation; either port (1 or 2) may 

be used. Although not required for operational purposes, if redundancy is 
desired, two UIMs may be installed in the Mini DSLAM.

3. Remove the slot cover from the selected port.

Store slot covers for possible future use. If a UIM is removed from a DSLAM, it 
must be replaced with either another UIM or a slot cover. Do not operate a 
Mini DSLAM with an open UIM slot.

4. Carefully slide the faceplate of the UIM under the inside lip of the Mini DSLAM 

at the selected port opening such that the UIM circuit board is face down and 
the UIM label shows through the port opening with the model name along the 
right edge.

5. Ensure the mounting holes on the UIM are lined up with the corresponding 

pems on the Mini DSLAM board and the board-to-board connector key pins 
are properly aligned.

6. Gently press down with even pressure on all four corners of the UIM until the 

board-to-board connector is fully seated.

Summary of Contents for UIM-10/100

Page 1: ...IVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge ESD during normal operation When performing installation procedures however take proper static control precautions to prevent damage to equipment If you are not sure of the proper static control precautions contact your nearest sales or service representative Unpack and inspect the equip...

Page 2: ...s if redundancy is desired two UIMs may be installed on the MUM 3 Remove the slot cover from the selected port Store slot covers for possible future use If a UIM is removed from a MUM it must be replaced with either another UIM or a slot cover Do not install a MUM with an open UIM port into an IP DSLAM 4 Carefully slide the faceplate of the UIM under the lip of the MUM faceplate at the selected po...

Page 3: ...ight screws securing the Mini DSLAM chassis and carefully lift off the chassis cover Set the screws aside 2 Select a port on the Mini DSLAM for UIM installation either port 1 or 2 may be used Although not required for operational purposes if redundancy is desired two UIMs may be installed in the Mini DSLAM 3 Remove the slot cover from the selected port Store slot covers for possible future use If ...

Page 4: ...on of the Lnk LED on the UIM faceplate indicates an Ethernet link has been established If the Lnk LED is illuminated but not the 100 LED then a 10 Mbps link has been established If the 100 LED is also illuminated then a 100 Mbps link has been established For most applications the UIM 10 100 connects to a router or a PC using a straight through Ethernet cable and to a hub or a switch using a crosso...

Page 5: ...e current information by fax or to speak with a company representative Within the U S A call 1 800 795 8004 Outside the U S A call 1 727 530 2340 Table 2 LEDs LED State Meaning Additional Information 100 solid green Fast Ethernet connection 100 Mbps is established If the 100 LED is illuminated the Lnk LED will also be illuminated no illumination no Fast Ethernet connection If the 100 LED remains u...

Page 6: ...ation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation If the equipment ...

Reviews: