Paradyne MIM-4T1 Installation Instructions Manual Download Page 8

8

 June 

2005

MIM4-A2-GZ41-00

LED Indicators

Table 1. LEDs

LED

STATE

INDICATION

ADDITIONAL 
INFORMATION

Lnk/Alm

(Port 1 – Port 4)

Flashing Green*

Connection is established 
and active.

Traffic is flowing.

Solid Green

Problematic connection.

A connection exists but no data 
is being passed.

No Illumination

Red Alarm. The incoming 
connection to the MIM has 
been lost; no data is being 
received.

If the outgoing connection from 
the MIM has also been lost 
then the remote T1 equipment 
to which the MIM is connected 
will be in Red Alarm as well.

Solid Amber

Yellow Alarm. The outgoing 
connection from the MIM 
has been lost; no data is 
being transmitted.

The remote T1 equipment has 
lost its incoming connection 
and is in Red Alarm.

Pulsing Amber

Blue Alarm. An indirect 
connection has been lost; 
the MIM may no longer be 
receiving data from the 
remote T1 equipment.

The remote T1 equipment has 
lost a connection with an 
intermediate device and is in 
Red or Yellow Alarm.

Act

(Port 1 – Port 4)

Flashing Green

Transmitting data.

Flashing Amber

Receiving data.

*

A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, 
less constant rate.

Summary of Contents for MIM-4T1

Page 1: ...cluding any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporation...

Page 2: ...UT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limitat...

Page 3: ...rts for the 4929 DSLAM or BSX8000 5 Broadband Services Switch NOTE All MIMs are hot swappable although removal of a MIM disengages the upstream network connection for the DSLAM Procedure 1 Using a fla...

Page 4: ...can only establish loop bonded connections with other loop bonding capable T1 provider equipment refer to the T1 Loop Bonding Product to Product Feature Compatibility list Document Number COMP A2 GK43...

Page 5: ...errite choke Position the choke as close as possible to the RJ48C connector Snap shut the ferrite choke 2 Plug your T1 cable into one of the T1 RJ48C ports on the MIM 4T1 Any port may be used 3 Verify...

Page 6: ...stem NMS Refer to the NMS User s Guide Document Number NMS A2 GB20 for detailed instructions Frame Type Frame type is the T1 data encapsulation method A frame consists of 193 bits 8 bit samples of eac...

Page 7: ...rings of zeros which can potentially cause loss of synchronization between units Paradyne products meet the North American minimum ones density requirement internally such that loss of synchronization...

Page 8: ...hich the MIM is connected will be in Red Alarm as well Solid Amber Yellow Alarm The outgoing connection from the MIM has been lost no data is being transmitted The remote T1 equipment has lost its inc...

Page 9: ...ch case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the eq...

Page 10: ...Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current information by fax or to speak with a company repres...