Paradyne MIM-4T1 Installation Instructions Manual Download Page 3

MIM4-A2-GZ41-00

June 2005

3

Unpacking and Inspecting the Equipment

HANDLING PRECAUTIONS FOR 
STATIC-SENSITIVE DEVICES

This product is designed to protect sensitive components from damage 
due to electrostatic discharge (ESD) during normal operation. When 
performing installation procedures, however, take proper static control 
precautions to prevent damage to equipment. If you are not sure of the 
proper static control precautions, contact your nearest sales or service 
representative.

If there is any visible damage, do not attempt to install the MIM-4T1; contact your 
sales representative.

Installing the MIM-4T1

The MIM-4T1 Micro Interface Module provides additional uplink ports for the 
4929 DSLAM or BSX8000-5 Broadband Services Switch.

NOTE: All MIMs are hot swappable, although removal of a MIM disengages the 
upstream network connection for the DSLAM.

Procedure

1. Using a flat-head screwdriver to loosen the fastening screws, remove the 

cover plate from the MIM port on the front of your 4929 or BSX8000.

CAUTION: The cover plate should be stored for possible future use: if the MIM 
is removed from your 4929 or BSX8000, it must be replaced with either 
another MIM or a cover plate. Do not operate a 4929 or BSX8000 with an 
open MIM port.

2. Align the MIM-4T1 with the module guides inside the MIM port.

3. Slide the MIM-4T1 firmly into place. Do not use excessive force.

4. Secure the MIM-4T1 by tightening the fastening screws on the MIM faceplate 

with a flat-head screwdriver.

!

MIM-4T1/E1

05-17671

Lnk/Alm 1 Act Lnk/Alm 2 Act Lnk/Alm 3 Act Lnk/Alm 4 Act

Summary of Contents for MIM-4T1

Page 1: ...cluding any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Paradyne Corporation...

Page 2: ...UT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT Some states or other jurisdictions do not allow the exclusion of implied warranties on limitat...

Page 3: ...rts for the 4929 DSLAM or BSX8000 5 Broadband Services Switch NOTE All MIMs are hot swappable although removal of a MIM disengages the upstream network connection for the DSLAM Procedure 1 Using a fla...

Page 4: ...can only establish loop bonded connections with other loop bonding capable T1 provider equipment refer to the T1 Loop Bonding Product to Product Feature Compatibility list Document Number COMP A2 GK43...

Page 5: ...errite choke Position the choke as close as possible to the RJ48C connector Snap shut the ferrite choke 2 Plug your T1 cable into one of the T1 RJ48C ports on the MIM 4T1 Any port may be used 3 Verify...

Page 6: ...stem NMS Refer to the NMS User s Guide Document Number NMS A2 GB20 for detailed instructions Frame Type Frame type is the T1 data encapsulation method A frame consists of 193 bits 8 bit samples of eac...

Page 7: ...rings of zeros which can potentially cause loss of synchronization between units Paradyne products meet the North American minimum ones density requirement internally such that loss of synchronization...

Page 8: ...hich the MIM is connected will be in Red Alarm as well Solid Amber Yellow Alarm The outgoing connection from the MIM has been lost no data is being transmitted The remote T1 equipment has lost its inc...

Page 9: ...ch case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the eq...

Page 10: ...Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current information by fax or to speak with a company repres...

Reviews: