20
Completing Setup From the NOC
Procedure
1.
Access the remote CSU/DSU on the TS Management Link that was set up at the
remote site in
2.
Ping the CSU/DSU five times within five seconds. The unit automatically accepts
the destination IP address of the ping as its temporary IP address.
3.
If necessary, open a Telnet session and configure any specific configuration options
that require input or changes from default settings.
Configuring SNMP Trap Managers and Traps
Procedure
To enter SNMP managers and configure traps:
1.
Select SNMP Traps.
Main Menu
→
Configuration
→
Management and Communication
→
SNMP Traps
2.
Configure the following:
—
Enable SNMP Traps.
—
Identify the total Number of Trap Managers.
—
Specify the IP address for each NMS Trap Manager to which traps will be sent.
—
Specify the Initial Route Destination for each Trap Manager. The default is
AutoRoute.
—
Select or disable trap categories, as needed.
3.
Save the configuration.