background image

12

 April 

2003

8799-A2-GZ40-10

For complete details about the configuration options, see the 

Hotwire 8799 TDM 

SHDSL Line Card, with G.703 Interface, User’s Guide

.

  

    

  

 

 

Select . . .

To Access the . . .

To Configure the . . .

Management and 
Communication

General SNMP Management 
Options (

Table 9)

SNMP NMS Security Options 
(

Table 10)

SNMP Traps Options 
(

Table 11)

Inband Management Channel 
Options (

Table 12

)

Management support of the 
card through SNMP and the 
Inband Management Channel.

Table 1. DSL Interface Options  (1 of 2)

Port Status

Possible Settings: 

Enable, Disable

Default Setting: 

Enable

Specifies whether the DSL port is operational.

Estimated Line Length

STU-C Only.
Possible Settings: 

short, medium, long

Default Setting: 

short

Determines the estimated line length for the distance from the local exchange. Estimated 
line length determines the speeds that can be supported.

Startup Margin

Possible Settings: 

0dB – 15dB

 

Default Setting: 

4dB

Specifies the Signal to Noise Ratio (SNR) margin a port must exceed to successfully train 
up with the remote unit.

Max DSL Rate

STU-C Only.

Determines the maximum speed of the DSL line.

Min DSL Rate

STU-C Only.

Determines the minimum speed of the DSL line.

Summary of Contents for Hotwire 8799

Page 1: ...otwire 8799 TDM SHDSL Line Card The Hotwire 8799 Line Card is a circuit card assembly that contains eight Time Division Multiplexer Symmetric High bit rate Digital Subscriber Line TDM SHDSL ports and...

Page 2: ...stalled and power is supplied to the chassis After the Hotwire TDM SHDSL Line Card is installed there are configuration procedures that must be performed before you can begin to use the card Refer to...

Page 3: ...the card For a Hotwire 8610 8620 DSLAM chassis Hold the Hotwire 8799 TDM SHDSL Line Card horizontally with the component side facing up and insert it into the left and right card guides 02 17114 MCP 8...

Page 4: ...service representative The card performs a power on self test All of the LEDs turn ON and OFF briefly When the self test is completed successfully the SYSTEM OK LED begins to pulse 5 If the LED is not...

Page 5: ...lease button and pull the connector away from the card 2 Feed the cable through the Cable Guide if it is in use When all cables are installed anchor them with cable ties to the rack DSLAM or Cable Gui...

Page 6: ...captive screw which is provided with the Hotwire DSLAM chassis 3 Insert a cable tie provided with Hotwire DSLAM chassis through the tie mount to hold the Telco 50 pin connector in place If more than...

Page 7: ...download is required Alrm Amber On Off Card failure or Power On Self Test POST is not complete or an alarm was reported on a DSL or G 703 port No alarms Test Amber On Off Slow cycling Loopback test or...

Page 8: ...e Hotwire 8799 TDM SHDSL Line Card s various ATI screens Main Status Test System and Test Status Performance Statistics Display LEDs Identity DSL Error Statistics DSL Performance Statistics Configurat...

Page 9: ...ch To access the Card Identity screen follow this menu selection sequence Main Menu Control Change Identity Configuring the Card Configuration option settings determine how the card operates Use the C...

Page 10: ...u select Then Current Configuration The selected configuration option set is loaded and the Configuration Edit Display menu screen appears Configuration Loader The Configuration Loader screen is displ...

Page 11: ...Threshold Trap Options Table 2 Threshold traps for the DSL ports 1 8 G 703 G 703 Interface Options Table 3 G 703 interface Copy Ports Copy Ports Options Table 4 DSL and G 703 interface ports by copyin...

Page 12: ...tions 1 of 2 Port Status Possible Settings Enable Disable Default Setting Enable Specifies whether the DSL port is operational Estimated Line Length STU C Only Possible Settings short medium long Defa...

Page 13: ...motely Initiated Loopback Possible Settings Enable Disable Default Setting Enable Specifies whether the line card will respond to a loopback command from the endpoint Peer IP Address Possible Settings...

Page 14: ...terval after which a trap will be sent LOSW Trap Threshold Possible Settings 1 900 or 0 to Disable Default Setting 0 Specifies the threshold for Loss of Sync Word Seconds events in a 15 minute interva...

Page 15: ...AMI HDB3 Default Setting HDB3 Specifies the line coding format to be used by the G 703 interface Line Framing STU C Only Possible Settings CRC4 noCRC4 Default Setting noCRC4 Specifies the framing for...

Page 16: ...nating Unit STU R NOTE Changing this option will reset the card Test Timeout Possible Settings Enable Disable Default Setting Enable Allows tests to end automatically The feature should be enabled whe...

Page 17: ...em Primary Clock Reference Possible Settings STU C G 703 Port 1 8 Internal Default Setting Internal Possible Settings STU R DSL Port 1 8 Internal Default Setting DSL Port 1 Specifies the primary clock...

Page 18: ...es in the Mode column refer to the ports entered as the source Cross Connect Mode Possible Settings DS1 Bypass DS1 Cross connect DS0 Cross connect Unassigned Disabled Default Setting DS1 Bypass Determ...

Page 19: ...elected port Only unassigned time slots can be selected Start TS Possible Settings 1 31 Default Setting Blank Specifies the time slot where time slot assignment is to begin in the contiguous time slot...

Page 20: ...er when that manager attempts to access an object in the MIB Name 1 Access STU R Only Possible Settings Read Read Write Default Setting Read Write Determines the access level for Community Name 1 Comm...

Page 21: ...of SNMP management systems attempting to access the node NMS n IP Address Possible Settings 001 000 000 000 223 255 255 255 Clear Default Setting 000 000 000 000 Specifies the Internet Protocol addres...

Page 22: ...the communication interfaces Link Trap Interfaces Possible Settings Network G 703 All Default Setting All Determines if the SNMP linkUp SNMP linkDown and interface related enterpriseSpecific traps ar...

Page 23: ...ce LMI the Inband Management Channel will use when Inband Management Type is set to Frame Relay Backup Inband Management Port Possible Settings 1 8 Default Setting 1 Selects the G 703 port for the bac...

Page 24: ...en The possible values are determined by whether Spectrum Management is enabled under System Options 2 Position the cursor in the Min DSL Rate field and choose from the available speeds listed at the...

Page 25: ...requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a volt...

Page 26: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the i...

Page 27: ...fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document...

Page 28: ...28 April 2003 8799 A2 GZ40 10 8799 A2 GZ40 10 8799 A2 GZ40 10...

Reviews: