background image

 9

8776-A2-GZ40-10

August 1998

— On a Hotwire 8800 DSLAM chassis:

SLOTS 13-18

SLOTS 7-12

SLOTS 1-6

98-15325-01

Anchor Mount

Telco 50-Pin

Connector

LINES

SLOTS 1-6

LINES

Shorter

Telco

Captive Screw

2. Replace the longer Telco cable captive screw with a shorter connector

captive screw, which is provided with the Hotwire DSLAM chassis.

3. Insert a cable tie (provided with Hotwire DSLAM chassis) through the tie

mount to hold the Telco 50-pin connector in place. If more than one Telco
cable is being connected, span the two or three connectors.

4. Make sure the other end is connected to the appropriate MDF or demarcation

point.

Refer to Appendix D, 

Cables and Pin Assignments, in the User’s Guide for

pinouts.

NOTE:

If you are connecting the Telco 25-pair, 50-pin cable to an MDF, a converter
may be necessary for terminating the other end of the cable on a punchdown
block before cross-connecting to an MDF.

Summary of Contents for Hotwire 8776 M/SDSL

Page 1: ...over traditional twisted pair telephone wiring HANDLING PRECAUTIONS FOR STATIC SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge ES...

Page 2: ...Operating temperature Storage temperature Relative humidity Shock and vibration 32 to 122 F 0 to 50 C 4 F 20 C to 158 F 70 C 5 to 85 noncondensing Withstands normal shipping and handling Technical sp...

Page 3: ...tion unit in Hotwire 8600 DSLAM base chassis Slot 2 or 3 Slot 1 of the Hotwire 8600 DSLAM base chassis must contain a Management Communications Controller MCC card Hotwire 8600 DSLAM expansion chassis...

Page 4: ...M A IN B DC FUSES 5 DC PWR FAN OUT SERIAL MCC 1 MANAGEMENT 3 LINE 1 2 3 98 15832a S Y S T E M O K A lr m T e s t T X R X C o l E T H E R N E T ESD 4 M SDSL 8776 S Y S T E M O K A lr m T e s t 1 2 3 1...

Page 5: ...ssages and Troubleshooting in the User s Guide 6 Secure the 8776 Termination Unit by fastening the screws at each end of the faceplate NOTE The 8776 Termination Unit may be replaced without system dis...

Page 6: ...OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes t 1 2 3 1 2 3 4 4 OK Alr m Tes...

Page 7: ...e card connector then push on the cable connector until it seats The end of the cable connector has a release button To remove the connector press the release button and pull the connector away from t...

Page 8: ...priate LINE port on the front panel of the chassis On a Hotwire 8600 DSLAM chassis 98 15833 01 A INPUT AC 48VDC CLASS 2 OR LIMITED PWR SOURCE RTN 48V A A B B LAN WAN SLOT 2 4 6 B 3 1 2 POSITION STACK...

Page 9: ...tie provided with Hotwire DSLAM chassis through the tie mount to hold the Telco 50 pin connector in place If more than one Telco cable is being connected span the two or three connectors 4 Make sure...

Page 10: ...Self Test POST is not complete No alarms Test Amber Amber flashing Off Loopback test or 511 test pattern in progress POST in progress No tests currently active G 703 1 2 3 4 Green Amber Amber flashin...