8774-A2-GZ40-30

February 2001

Installing TDM SDSL Cards

A Hotwire 8774 TDM SDSL Termination Unit can be installed, removed, and
replaced from a the DSLAM chassis without disrupting service to the other cards
in the chassis.

"

Procedure

To install the unit:

1. Determine in which slot the unit will be installed. Verify that cards in adjacent

slots have been fastened.

2. Remove the filler plate from the installation slot and store for possible later

use.

3. Insert the unit into the DSLAM:

— For a Hotwire 8600 Series DSLAM chassis – Hold the unit horizontally,

with the component side facing up, and insert it into the left and right card
guides.

— For a Hotwire 8800 Series DSLAM chassis  Hold the unit vertically,

with the component side facing right, and insert it into the top and bottom
card guides.

4. Slide the unit into the slot until the power and network connectors seat firmly

in the mating connectors on the backplane.

CAUTION:

Do not force the unit into the slot. This can damage the backplane
connectors. If the card does not seat properly, remove the card and
reinstall it. If it still does not seat properly, call your service
representative.

The termination unit performs a power-on self-test. All of the LEDs turn ON
and OFF briefly. When the self-test is completed successfully, the SYSTEM
OK LED begins to pulse once per second.

5. If the LED is not pulsing, refer to Messages and Troubleshooting in the User’s

Guide.

6. Secure the unit by fastening the screws at each end of the faceplate.

Summary of Contents for Hotwire 8774

Page 1: ...Unit The Hotwirer 8774 Termination Unit is a circuit card assembly that contains four Time Division Multiplexer Symmetric Digital Subscriber Line TDM SDSL ports and a DSX 1 interface When the termina...

Page 2: ...Hotwire DSLAM chassis is installed and power is supplied to the chassis After the Hotwire 8774 TDM SDSL Termination Unit is installed there are configuration procedures that must be performed before...

Page 3: ...a Hotwire 8800 Series DSLAM chassis Hold the unit vertically with the component side facing right and insert it into the top and bottom card guides 4 Slide the unit into the slot until the power and n...

Page 4: ...otwire DSLAM chassis containing the Hotwire 8774 TDM SDSL Termination Unit to an MDF or other demarcation point Do not connect it to a POTS splitter Procedure To connect the Hotwire DSLAM chassis cont...

Page 5: ...Loopback test or 511 test pattern in progress POST in progress No tests DSX 1 1 2 3 4 Green On Slow cycling Fast cycling Off Recoverable signal present on the DSX 1 network Yellow Alarm Indication RAI...

Page 6: ...illustration shows the paths to the Hotwire 8774 TDM SDSL Termination Unit s various ATI screens Main Status Test System and Test Status Performance Statistics Display LEDs Identity Network Error Stat...

Page 7: ...selection sequence Main Menu Control Change Identity Configuring the TDM SDSL Termination Unit Configuration option settings determine how the unit operates Use the Configuration branch of the Hotwir...

Page 8: ...nfiguration Configuration Loader Default Factory Configuration Ctrl a to access these functions ESC for previous menu MainMenu Exit Make a selection by placing the cursor at your choice and pressing E...

Page 9: ...em Options Management and Communication Ctrl a to access these functions ESC for previous menu MainMenu Exit Save Select To Access the To Configure the Network Network Interface Options Table 1 T1 TDM...

Page 10: ...at the rate in the DSL Line Rate field The automatically set rate cannot exceed DSL Line Rate H AutoRate is only available when the unit is configured as an LTU DSL Line Rate Possible Settings 400 52...

Page 11: ...s 1E 4 1E 5 1E 6 1E 7 1E 8 1E 9 Default Setting 1E 4 Determines the error rate at which an excessive error rate EER condition is recognized The rate is the ratio of the number of CRC5 errors to the nu...

Page 12: ...ettings Enable Disable Default Setting Enable Allows tests to end automatically The feature should be enabled when the unit is remotely managed so that control can be regained after a test is accident...

Page 13: ...ssion Login IDs are created with a password and access level Session Access Level Possible Settings Administrator Operator Default Setting Administrator The Telnet session access level is interrelated...

Page 14: ...rnal SNMP manager when that manager attempts to access an object in the MIB Name 1 Access Possible Settings Read Read Write Default Setting Read Determines the access level for Community Name 1 Commun...

Page 15: ...Possible Settings 1 2 3 4 5 6 7 8 9 10 Default Setting 1 Specifies the number of SNMP management systems that can send SNMP messages NMS n IP Address Possible Settings 001 000 000 000 223 255 255 255...

Page 16: ...ettings IMC DSL1 DSL2 DSL3 DSL4 Default Setting IMC Provides the network destination path of each trap manager H NMS n Destination is available only when the unit is configured as an NTU and not runni...

Page 17: ...y requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a vo...

Page 18: ...may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the...

Page 19: ...by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this docum...

Reviews: