Paradyne Hotwire 8774 Installation Instructions Manual Download Page 2

 2

8774-A2-GZ40-30

February 2001

Installation Overview

Installation and configuration of the Hotwire 8774 TDM SDSL Termination Unit
consists of:

H

Installing the unit in the DSLAM.

H

Connecting to the DTE.

H

Connecting to an MDF.

H

Providing initial unit identity information or changing existing identity
information.

H

Configuring your unit using the Configuration Edit menus.

Before you install the Hotwire 8774 TDM SDSL Termination Unit, read the
Important Safety Instructions on page 17.

Be sure to register your warranty at www.paradyne.com/warranty.

Planning the Installation

Review the following list to help plan for the installation.

-

Obtain the applicable cables; refer to Cables You Need, below.

-

Make sure the Hotwire DSLAM chassis is installed and power is supplied to
the chassis.

-

After the Hotwire 8774 TDM SDSL Termination Unit is installed, there are
configuration procedures that must be performed before you can begin to use
the unit. Refer to the Hotwire 8774 TDM SDSL Unit, with DSX-1 Interface,
User’s Guide
 if you need detailed configuration procedures.

Cables You Need

The following standard cables are used with this product.

For the network connection:

H

Plug-ended Telco 50-position cable for connection from the Hotwire 8600
Series DSLAM LINE port or one of the Hotwire 8800 Series DSLAM LINES
ports to the Main Distribution Frame (MDF) or other demarcation point.

For the DTE connection:

H

The 50-position plug to four 8-position non-keyed jacks (like Paradyne
Feature No. 8700-F1-505).

For further information refer to Connector Pin Assignments in the User’s Guide,
and the appropriate DSLAM installation document.

Summary of Contents for Hotwire 8774

Page 1: ...Unit The Hotwirer 8774 Termination Unit is a circuit card assembly that contains four Time Division Multiplexer Symmetric Digital Subscriber Line TDM SDSL ports and a DSX 1 interface When the termina...

Page 2: ...Hotwire DSLAM chassis is installed and power is supplied to the chassis After the Hotwire 8774 TDM SDSL Termination Unit is installed there are configuration procedures that must be performed before...

Page 3: ...a Hotwire 8800 Series DSLAM chassis Hold the unit vertically with the component side facing right and insert it into the top and bottom card guides 4 Slide the unit into the slot until the power and n...

Page 4: ...otwire DSLAM chassis containing the Hotwire 8774 TDM SDSL Termination Unit to an MDF or other demarcation point Do not connect it to a POTS splitter Procedure To connect the Hotwire DSLAM chassis cont...

Page 5: ...Loopback test or 511 test pattern in progress POST in progress No tests DSX 1 1 2 3 4 Green On Slow cycling Fast cycling Off Recoverable signal present on the DSX 1 network Yellow Alarm Indication RAI...

Page 6: ...illustration shows the paths to the Hotwire 8774 TDM SDSL Termination Unit s various ATI screens Main Status Test System and Test Status Performance Statistics Display LEDs Identity Network Error Stat...

Page 7: ...selection sequence Main Menu Control Change Identity Configuring the TDM SDSL Termination Unit Configuration option settings determine how the unit operates Use the Configuration branch of the Hotwir...

Page 8: ...nfiguration Configuration Loader Default Factory Configuration Ctrl a to access these functions ESC for previous menu MainMenu Exit Make a selection by placing the cursor at your choice and pressing E...

Page 9: ...em Options Management and Communication Ctrl a to access these functions ESC for previous menu MainMenu Exit Save Select To Access the To Configure the Network Network Interface Options Table 1 T1 TDM...

Page 10: ...at the rate in the DSL Line Rate field The automatically set rate cannot exceed DSL Line Rate H AutoRate is only available when the unit is configured as an LTU DSL Line Rate Possible Settings 400 52...

Page 11: ...s 1E 4 1E 5 1E 6 1E 7 1E 8 1E 9 Default Setting 1E 4 Determines the error rate at which an excessive error rate EER condition is recognized The rate is the ratio of the number of CRC5 errors to the nu...

Page 12: ...ettings Enable Disable Default Setting Enable Allows tests to end automatically The feature should be enabled when the unit is remotely managed so that control can be regained after a test is accident...

Page 13: ...ssion Login IDs are created with a password and access level Session Access Level Possible Settings Administrator Operator Default Setting Administrator The Telnet session access level is interrelated...

Page 14: ...rnal SNMP manager when that manager attempts to access an object in the MIB Name 1 Access Possible Settings Read Read Write Default Setting Read Determines the access level for Community Name 1 Commun...

Page 15: ...Possible Settings 1 2 3 4 5 6 7 8 9 10 Default Setting 1 Specifies the number of SNMP management systems that can send SNMP messages NMS n IP Address Possible Settings 001 000 000 000 223 255 255 255...

Page 16: ...ettings IMC DSL1 DSL2 DSL3 DSL4 Default Setting IMC Provides the network destination path of each trap manager H NMS n Destination is available only when the unit is configured as an NTU and not runni...

Page 17: ...y requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a vo...

Page 18: ...may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the...

Page 19: ...by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this docum...

Reviews: