3. Configuration
8335-A2-GB20-A0
March 2005
3-27
4. Save the changes as prompted.
SNR Margin Threshold
A number from
0
to
15
(Default = 0).
If the Signal-to-Noise (SNR) ratio (in dB) reaches or drops
below the selected value, an SNMP trap is sent.
Attenuation Threshold
A number from
0
to
127
(Default = 0).
If the Attenuation reaches or drops below the selected
value, an SNMP trap is sent.
Link Down Count
A number from
0
to
900,
or a
D
for Disable
(Default = 0).
If the number of DSL Link Down events exceeds the
selected number within a 15-minute period, an SNMP trap
(Enterprise trap xdslLinkUpDownTransitions(1)) is sent. If
Link Down Count is set to Disable or 0, no Link Down trap is
ever sent. If set to 1, a trap is sent after each
linkUpDownTransition event.
Link Up/Down Trap
Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable
– Enables link up/down traps.
Disable
– Disables link up/down traps.
Remote Management
Enable or Disable to enable/disable support for remote
management of devices on the SHDSL line from the STU-R
via the Embedded Operations Channel (EOC) (Default =
Enable).
Enable
– Enables remote management support.
Disable
– Disables remote management support.
For . . .
Enter . . .