2. Web Server Interface
2-4
April 2003
8300-A2-GB20-00
The Unit screen provides the following user-activated buttons:
Maintenance Reset
Use this button to perform a Maintenance Reset. All configurations will be lost and
the unit will be set back to an initial factory configuration. There are five options for
a Maintenance Reset as shown in the table below.
* Factory default configuration
All the factory configurations set up an ATM service on the Network port with one
configured virtual channel (VPI=0, VCI=32). Management data received on this
channel (either WEB or SNMP) will be processed at the unit if it is encapsulated
using RFC 1483 and directed to the unit’s IP address. (A Maintenance Reset will
not change the unit’s IP address.)
The Serial HDLC configuration and the T1 CBR configuration will also accept
PPPoA encapsulated data and deliver it to the Serial port.
The T1 CBR, E1 CBR, and Serial CES configurations set up a CES service
between the Network port and the T1/E1 CBR port or the Serial port using VPI=0,
VCI=33. The T1 CBR configuration sets up the CBR port to run T1 and has 24
channels delivered to the CES service. The E1 configuration sets up the CBR port
to run E1 and has 31 channels delivered to the CES service. The Serial CES
configuration sets up the CBR port to run E1, but allocates Channels 1
−
31 to the
Serial port.
Clicking the Maintenance Reset button will display a selection screen with a
drop-down list of the available configurations as shown in
Figure 2-2
.
Button
Function
Submit
Sets any values that have been changed. Use the top Submit
button to set unit parameters changed in the upper section of the
screen, and the lower Submit button to set the real-time clock.
Maintenance Reset
Resets unit to its default configuration.
Save and Restart
Saves the current configuration and restarts the unit.
Configuration
Choice
RFC 1483
Encapsulated
Data
IP
Encapsulated
in ATM
Serial HDLC
Encapsulated
in ATM
T1 CBR
Channels
E1 CBR
Channels
Serial CBR
Channels
Ethernet
Yes
Yes
No
None
None
None
Serial HDLC
Yes
No
Yes
None
None
None
T1 CBR*
Yes
No
Yes
1
−
24
None
None
E1 CBR
Yes
Yes
No
None
1
−
31
None
Serial CES
Configuration
Yes
Yes
No
None
None
1
−
31