Configuration Option Tables
A-6
7985-A2-GB20-00
October 1998
Table A-2.
Synchronous Data Port Options (3 of 3)
Port (DTE) Initiated Loopbacks
Possible Settings: Disable, DTLB, DCLB, Both
Default Setting: Disable
Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or
remote Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB is
equivalent to a V.54 loop 3, and DCLB is equivalent to a V.54 loop 2.) Control of these
loopbacks is through the DTE interchange circuits as specified by the V.54 standard.
Disable – Disables control of local DTLBs and remote DCLBs by the DTE connected to
this port.
DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port.
This loopback is controlled by the Local Loopback interchange circuit LL (CCITT 141).
DCLB – Gives control of the remote DCLBs for the far-end port connected to this port to
the DTE attached to this port. This loopback is controlled by the Remote Loopback
interchange circuit RL (CCITT 140). The far-end equipment must support in-band
V.54 loopbacks.
Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to this
port.