![Paradyne HOTWIRE 7925 User Manual Download Page 40](http://html2.mh-extra.com/html/paradyne/hotwire-7925/hotwire-7925_user-manual_3784614040.webp)
Testing
7-3
7925-A2-GB20-30
PRELIMINARY DRAFT
June 1997
Remote Loopbacks
When remote loopback is enabled the red Loop Bk LED on the front panel of the
remote-end unit (CO or CP) lights up and remains lit until the loopback is
disabled. The loopback LED on the initiating unit does not light.
Figure 7-3 illustrates remote loopback from a CO unit in a connection between
two units of the same compatibility (either two G.703-compatible units or two
V.35-compatible units).
Terminal
97-15259-01
CO
CP
E1 HDSL
7900
7900
Diagnostic
Equipment
E1 HDSL
7900
7900
Diagnostic
Equipment
Loop Bk
LED lights
Figure 7-3.
Remote Loopback from CO End, Two Like Units