15
5.
If the network cable length is longer than 100 ft (30 m), set the Network 1 Line Build
Out to Long.
6.
If the DTE cable length is longer than 100 ft (30 m), set the Port 1 Line Build Out to
Long.
7.
Save the configurations.
8.
Install the network cable (see
Connecting to the Network
on page 17). The
FrameSaver unit starts discovering DLCIs (see
Automatic Configuration
on
page 17).
9.
If the Ethernet port will be used for management, install the Ethernet cable (see
Connecting the LAN Cable
on page 20).
10.
Install the DTE cable (see
Connecting to the DTE
on page 20).
Physical installation of the unit is complete; the NOC can now remotely access the unit
for additional configuration.
Completing Setup of the Unit From the NOC
Procedure
1.
Access the remote FrameSaver unit on the dedicated network management link,
using the Node IP Address.
2.
Configure specific frame relay options, like CIR (Committed Information Rate) or
traffic policing, and any other configuration options requiring input or changes from
the default settings.
3.
Configure SNMP traps.
4.
Save the configurations.
5.
Verify the entire path from the FrameSaver unit to the NOC NMS is functioning (see
Verifying the End-to-End Path
on page 19).
6.
Verify that data is being received (see
Checking that Data is Being Received
on
page 22
).
7.
Verify that all PVCs, including Management PVCs, are configured (see
Checking
PVC Connections
on page 22).