Troubleshooting
11-17
9124-A2-GH30-00
June 1999 - Preliminary
Starting and Stopping a Test
Use this procedure to start, monitor, or abort specific tests. To abort all active
tests on all interfaces, see
Aborting All Tests
on page 11-18.
When the status of a test is . . .
The only command available is . . .
Inactive
Start
Active
Stop
Start or stop an individual test using the same procedure.
"
Procedure
To start and stop a loopback or a set-pattern test:
1. Follow this menu selection sequence:
Main Menu
→
Test
2. Select an interface to be tested (Network, Data Port, or ISDN PVC Tests, or
Network, Data Port, DSX-1, or PRI Physical Tests) and press Return.
The selected test screen appears. Start appears in the Command column.
Inactive appears in the Status column.
3. Select the Port number and press Return.
4. Select the DLCI number and press Enter if a PVC test has been selected.
The cursor is positioned at Start in the Command column of the first available
test. Start is highlighted.
5. Highlight the Start command for the test you want to start and press Enter.
Stop now appears and is highlighted, and the status of the test changes to
Active.
6. Press Enter to stop the test.
Start reappears and the status of the test changes back to Inactive.
7. View the length of time that the test has been running in the Result column.
Summary of Contents for FrameSaver SLV 9124
Page 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Page 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Page 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...