Setting Up Service Provider Connectivity
at the Central Site
When management needs to be set up between a service provider’s customer and its
network operations center (NOC), a non-multiplexed DLCI must be configured to carry
management data between the customer’s central site and the NOC console. This
requires that a frame relay discovered DLCI needs to be modified. This is because all
auto-configured network DLCIs are configured as multiplexed DLCIs.
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration
→
Network
→
DLCI Records
2. Select Modify. The
Modify DLCI Record for DLCI Number
prompt appears.
3. Select the DLCI that will be used by pressing the spacebar until the correct DLCI
number appears, then select it.
4. Change the DLCI Type from Multiplexed to Standard.
The
DLCI in connections. Update DLCI usage as follows:
prompt
appears.
5. Select the
Delete EDLCI Connections and Make a Mgmt Only PVC
option.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to
this network DLCI and the embedded management DLCI (EDLCI) are deleted, and
the selected DLCI will be reconfigured as a management PVC using the Node IP
Address.
Configuring SNMP Trap Managers and Trap Dial-Out
Once the FrameSaver unit is connected to the network, SNMP trap managers, SNMP
traps, and trap dial-out can be configured.
1. Select SNMP Traps.
Main Menu
→
Configuration
→
Management and Communication
→
SNMP Traps
2. Configure the following:
– Enable SNMP Traps.
– Identify the total Number of Trap Managers.
– Specify the IP address of the NMS(s) to which traps will be sent.
– Specify the network Destination for the Trap Manager(s).
– Select desired trap categories.
3. Save the configuration.
4. Return to the Main Menu.